![Flowserve Gestra GAV 56F Installation Instructions Manual Download Page 15](http://html1.mh-extra.com/html/flowserve/gestra-gav-56f/gestra-gav-56f_installation-instructions-manual_2308393015.webp)
15
Apply a grease gun to the lubricating nipple in
the locking screw (2).
Removing external dirt deposits
To pump grease into the equipment squeeze the
grease gun handle once or twice.
CAUTION
Hot surfaces and heat radiation present
the risk of burns.
Wear protective gear that is suitable
for the temperatures generated in your
plant.
Remove any excess grease around the
lubricating nipple with a soft cloth.
2
To remove dirt deposits rinse the equipment
with fresh water and wipe it with a clean, lint-
free cloth.
To remove any persistent residues use a
cleaning agent that is suitable for the material
and carefully wipe the equipment with a clean,
lint-free cloth.
Maintaining the equipment
Servicing the equipment and
installing spare parts
CAUTION
Hot surfaces and heat radiation present
the risk of burns.
Wear protective gear that is suitable
for the temperatures generated in your
plant.
No spare parts are available for the equipment.
Replace a defective device with a new one.
Turn the handwheel every six months to both
stops.
You can increase the service life of the equipment
by applying a suitable lubricant to all moving parts.
A suitable lubricant is, for example, Klüber HEL46-