FM USER INSTRUCTIONS ENGLISH 71576526 - 03/07
Page 11 of 32
flowserve.com
All motors (for masses see the motor
description plate) must be handled with a winch.
For masses above 25 kg (55 lb), manual
handling is forbidden.
2.3 Lifting
2.3.1 Slinging of motor pumps units
Use handling means in accordance with motor
pump unit mass mentioned on the CE plate. For the
masses of the pumps bare end of shaft see table §
2.2.2 and nameplate.
To avoid distortion, lift up motor
pump unit as shown:
Motor pump unit
When handling always wear gloves, safety
boots and an industrial safety helmet.
For masses above 25 kg (55 lb), manual
handling is forbidden.
2.4 Storage
Store the pump in a clean, dry
location away from vibration. Leave piping
connection covers in place to keep dirt and other
foreign material out of pump casing. Turn pump at
intervals to prevent brinelling of the bearings and the
seal faces, if fitted, from sticking.
Do not store pumps starting on the fan guard.
The pump may be stored as above for up to 6
months. Consult Flowserve for preservative actions
when a longer storage period is needed.
2.5 Recycling and end of product life
At the end of the service life of the product or its parts,
the relevant materials and parts should be recycled or
disposed of using an environmentally acceptable
method and local regulations.
If the product contains substances which are harmful
to the environment, these should be removed and
disposed of in accordance with current regulations.
This also includes the liquids and or gases in the
"seal system" or other utilities.
Make sure that hazardous substances or toxic
fluids are disposed of safely and that the correct
personal protective equipment is used. The safety
specifications must be in accordance with the current
regulations at all times.
3 PUMP DESCRIPTION
3.1 Description and restrictions of use
The multi-stage centrifugal pump is designed for the
pumping of cold water or all clear liquids which are
not solid and liquid mixtures, non-corrosive, non-
abrasive or non-explosive when in contact with the
pump motor unit and its working parts (Important: for
other liquids consult Flowserve for beforehand
advice).
The FM type is a centrifugal, multi-stage, close -
coupled pump with an axial inlet and a vertical axis
outlet.
The pump must be stored in a non explosive,
ventilated location, sheltered from bad weather, dust
and vibrations.
The reliability of the delivered machine can only be
ensured if it is used according to the conditions
given in this manual. The maximum values specified
in this manual must never be exceeded.