![Flowplant 003301 Operation & Maintenance Manual Download Page 15](http://html1.mh-extra.com/html/flowplant/003301/003301_operation-and-maintenance-manual_2308330015.webp)
15
3. Technical Data
3.1. Technical data
3.1.1. Pump Data
Pump Type
P Type 6 22 (See Section 8)
Pump width
405 mm
Pump length
385 mm
Inlet
28.6 mm dia
Outlet
G1/2” (1/2” BSP)
Shaft dia
30 mm
Shaft length
65 mm
No. of cylinders
6
Piston diameters
22 mm
Maximum pressure
200 Bar
Nominal Flow rate
45 lpm
Crankcase lubrication
Fully immersed
Oil capacity (litres)
5.0 litres
Weight (kg)
80 kg
Recommended crankcase oil
Shell Morlina 150 or Tellus 150 (see
section 6)
Max inlet pressure
0.5 bar (5.0 metre head)
Max inlet temp.
25°C
Prime Mover
Kubota D1105-E4B-EU-X1 18.5kW Stage 5 C-TXT
Drive
Gearbox Harben (2.0:1)
Water Tank
Capacity 88 gals. (400 litres)
Supply Water Filter
N05105 Hypro line strainer / 177 micro mesh
Pressure Gauge
Digitally Displayed
Safety Relief
Hawk (Automatic SRV)
Mains Water Supply
Positive head.
Note: Water pH value of 5 to 9 is recommended.
Summary of Contents for 003301
Page 11: ...11 Hydraulic Diverter Valve 069 581 ...
Page 12: ...12 Hawk Safety Relief Valve 035 401 ...
Page 13: ...13 Speck Unloader Valve UL221 035 185 ...
Page 25: ...25 Fig 4 Operating with the Radio Remote ...
Page 43: ...43 9 Circuit and Wiring Diagrams ...
Page 45: ...45 ...
Page 46: ...46 ...
Page 59: ...59 ...
Page 61: ...61 ...
Page 62: ...62 11 Service Documents 11 1 Service Checklist ...
Page 63: ...63 11 2 Service Logbook ...
Page 64: ...64 ...