![FlowMotion 2001V Series Installation And Operation Manual Download Page 11](http://html.mh-extra.com/html/flowmotion/2001v-series/2001v-series_installation-and-operation-manual_2308326011.webp)
6.
Remove and inspect collet for wear. Note that the collet
may remain in the roller assembly when the roller
assembly is removed from the pump shaft.
7.
Clean inside of pump housing with damp rag or an
appropriate cleaning solution to remove any chemical or
tubing residue.
Reassembly
:
1. Reinstall the collet onto the pump shaft.
There is a slot in the collet that the flat drive tang on the
gearbox shaft must slide into. Orient the collet to allow the
drive tang to slide into the slot and push the collet completely
onto the gearbox shaft. When the collet bottoms out it is in the
correct position.
Summary of Contents for 2001V Series
Page 1: ...2001V Series Peristaltic Chemical Feed Pump ...
Page 2: ......