background image

  Step Two

DIMENSIONS

10' Cable

 (3m)

3.0"

(76mm)

2.3"

(57mm)

4.7"

(120mm)

0.

7"

(1

8m

m

)

3/4" NPT (3/4" G)

3/4" NPT (3/4" G)

0.7"

(19mm)

2.8"

(71mm)

2.1"

(54mm)

4.5"

(114mm)

3/4" NPT (3/4" G)

3/4" NPT (3/4" Rp)

10' Cable

 (3m)

1.3"

(32mm)

10' Cable

 (3m)

0.7"

(19mm)

0.7"

(19mm)

3.0"

(76mm)

3/4" NPT (3/4" Rp)

3/4" NPT (3/4" Rp)

5.0"

(127mm)

2.6"

(67mm)

3.3"

(83mm)

0.7"

(19mm)

3/4" NPT (3/4" G)

3/4" NPT (3/4" Rp)

10' Cable

 (3m)

4.5"

(114mm)

2.1"

(54mm)

2.8"

(70mm)

0.7"

(19mm)

3/4" NPT (3/4" G)

3/4" NPT (3/4" Rp)

10' Cable

 (3m)

3.0"

(76mm)

1.3"

(32mm)

10' Cable

 (3m)

0.7"

(19mm)

0.7"

(19mm)

3/4" NPT (3/4" Rp)

3/4" NPT (3/4" Rp)

4.5"

(114mm)

2.1"

(54mm)

2.8"

(71mm)

0.7"

(19mm)

3/4" NPT (3/4" G)

3/4" NPT (3/4" Rp)

10' Cable

 (3m)

3.0"

(76mm)

1.3"

(32mm)

10' Cable

 (3m)

0.7"

(19mm)

0.7"

(19mm)

3/4" NPT (3/4" Rp)

3/4" NPT (3/4" Rp)

Switch-Tek™ Optic Leak Detection Switch, LO10 Series

Switch-Tek™ Intrusive RF Capacitance Level Switch, LP10 Series

Switch-Tek™ SuperGuard RF Capacitance Level Switch, LP15 Series

Switch-Tek™ Ultrasonic Level Switch, LU10 Series

Switch-Tek™ Vibration Level Switch, LZ12 Series

* all dimensions are Nominal

Spec Tech Industrial Electric               www.spectechind.com

888-773-2832

Spec Tech Industrial Electric               www.spectechind.com

888-773-2832

Summary of Contents for Switch-Tek LO10 Series

Page 1: ...ct returned to Flowline where a There is evidence of a potentially hazardous material present with product b The product has remained unclaimed at Flowline for longer than 30 days after dutifully requesting disposition of the product THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS WARRANTY This warranty and the obligations and liabilities of Flowline under it are ex...

Page 2: ... Class 1 Division 1 Groups A B C D EEx ib IIC T6 CSA Vmax 32V Imax 300 mA Pmax 1 3 W Ci 0 F Li 0 H EEx Ui 32V Ii 300 mA Pi 1 3 W Ci 0 F Li 0 H CSA LR 79326 EEx LCIE 01 E6048 X Dielectric range Conductive range Sensor material Cable jacket mat 20 constants 100 micromhos PP PP Switch Tek Guard RF Capacitance Level Switch LP15 Series Dielectric range Conductive range Sensor material Cable jacket mat ...

Page 3: ...Cable 3m 0 7 19mm 0 7 19mm 3 4 NPT 3 4 Rp 3 4 NPT 3 4 Rp 4 5 114mm 2 1 54mm 2 8 71mm 0 7 19mm 3 4 NPT 3 4 G 3 4 NPT 3 4 Rp 10 Cable 3m 3 0 76mm 1 3 32mm 10 Cable 3m 0 7 19mm 0 7 19mm 3 4 NPT 3 4 Rp 3 4 NPT 3 4 Rp Switch Tek Optic Leak Detection Switch LO10 Series Switch Tek Intrusive RF Capacitance Level Switch LP10 Series Switch Tek SuperGuard RF Capacitance Level Switch LP15 Series Switch Tek Ul...

Page 4: ...ly Vibration Switch The Tuning Fork vibration switch operates at a nominal frequency of 400 Hz As the switch becomes immersed in a liquid or slurry a cor responding frequency shift occurs When the measured frequency shift reaches the set point value the switch changes state indicating the presence of a liquid or slurry medium For optimum performance and proactive maintenance the sensor automatical...

Page 5: ... fitting which enables users to install up to four FLOWLINE sensors of any technology to any depth along the entire length of track Smart Trak may be installed through the top wall of any tank using a standard 2 NPT tank adapter If no tank top installation is available Flowline s side mount bracket LM50 1001 enables Smart Trak to be installed directly to the side wall of a tank Do not use PFA Tefl...

Page 6: ... wires Complete the circuit by either con necting the Green to VDC power or White to VDC power see illustration below Switching a Normally Open AC Load The Red wire connects to Positive of the DC power supply and the Black wire connects to Negative The LOAD can be attached to the Green wire and the Hot of the VAC power Connect the White to the Neutral of the VAC power see illustration below Switch...

Page 7: ...LU10 ___5 are North America Europe Vmax 32 VDC Ui 32 VDC Imax 0 5 A Ii 0 5 A Pmax 1 3 W Pi 1 3 W Ci 0 µF Ci 0 µF Li 0 µH Li 0 µH Intrinsically Safe Control Drawing Red Wire Black Wire Shield HAZARDOUS LOCATION Class I Division1 Groups A B C D EEx ib IIC T6 NON HAZARDOUS LOCATION Sensor Drawing U10900 Sheet 1 of 2 Rev B 4 02 01 Sensor Models LU10 ___5 Entity Parameters North America Vmax 32V Imax 3...

Page 8: ...e power supply and the Black wire connects to Negative The Green wire is jumpered to the Red wire while the White wire is connected to the LOAD Jumper the LOAD back to the Negative to complete the circuit Dry Condition Sensor NO RED GRN SHLD WHT BLK LOAD SENSOR POWER RED BLK Wires 36 VDC Max 5 1 mA Dry 19 1 mA Wet RELAY RATING GRN WHT Wires 60 VA Max Dry Condition Sensor NO BLK GRN SHLD WHT RED LO...