Step Four

ASSEMBLY OF SWITCH PAK™

Step Three

SAFETY PRECAUTIONS

About this Manual:  

PLEASE READ THE ENTIRE MANU-

AL PRIOR TO INSTALLING OR USING THIS PRODUCT.  This
manual includes information on the Switch Pak™ with Compact
Relay Controller: AU13-_2__, AZ13-_2__ and AV13-_2__.  The
units are identical except for the material of construction, choice of
Strobe Alert and the sensors technology.

User's Responsibility for Safety:  

Flowline manufactures

a wide range of liquid level sensors, controllers, and mounting sys-
tems. It is the user's responsibility to select components that are
appropriate for the application,  install them properly, perform tests
of the installed system, and maintain all components. The failure to
do so could result in property damage or serious injury. 

Proper Installation and Handling:  

Use a proper sealant

with all installations. Never overtighten the components. Always
check for leaks prior to system start-up. 

Material Compatibility:

Polypropylene (PP, a polyolefin): Sensor, Switch Pak™ fitting,
Controller Housing.

Polyvinylidene Fluoride (PVDF): Sensor and SWitch Pak™ fitting.

Viton (a fluorocarbon): O-ring.

Make sure that the application liquids are compatible with the
materials that will be wetted.  To determine the chemical compati-
bility between the components and its application liquids, refer to
the Compass Corrosion Guide, available from Compass
Publications (phone 858-589-9636).

Temperature and Pressure:  

Switch Pak™ is designed for

use in application temperatures up to 90° C (194° F).  The Vibration
and Ultrasonic packages are designed for pressurized applications
up to 150 psi (10 bar) and the Buoyancy package is designed for
use up to 25 psi (1.7 bar).

Wiring and Electrical:  

Electrical wiring of any liquid level

control system should be performed in accordance with all applic-
able national, state, and local codes. Take care not to cut or break
the outer insulation jacket of wiring that may be immersed while
routing cables in the Switch Pak™ system. Such breaks of the liq-
uid seal of the sensor system may lead to component failure.

Flammable, Explosive and Hazardous Applications:

The AU13-_2__, AV13-_2__ and AZ13-_2__  Switch Pak™
should not be used within classified hazardous environments. 

Make a Fail-Safe System: 

Design a fail-safe system that

accommodates the possibility of system or power failure. In criti-
cal applications, Flowline recommends the use of redundant back-
up systems and alarms in addition to the primary system.

About Switch Pak™:

Flowline’s Switch Pak™ with Compact

Relay Controller Assembly is an single-point mounting system for
installing one level sensor vertically within a tank.  The compact relay
controller features a 120/240 VAC controller with a 250 VAC, 10A
SPDT relay contract.  Switch Pak™ mounts vertically through a stan-
dard 2" NPT (1 1/2” G) tank adapter, or on a side mount bracket (such
as the LM50-1001). 

Relay Controller:  

The level switch is

pre-wired before shipment to the 2-pole ter-
minal strip [Input 1 (+) & (-)]. The switch
technologies used to indicate level are either
Ultrasonic, Buoyancy or Vibration.  The
Compact Relay Controller provides a 1/2”
Conduit connection and 6 poles for wire ter-
mination of power and relay contact.  Use the
AC, AC and GND terminals for providing
power.  Use the NC, NC and COM terminals
for interfacing to the relay contact.

Vibration (LZ12-1405) 
Wire Configuration:

RELAY

Red

Black

White

Green

Orange

(+)

(-)

N/A

N/A

N/A

Shld

RELAY

(+)

(-)

N/A

N/A

Shld

Red

Black

White

Green

REED

N/A

(-)

(+)

Shld

Red

Black

White

Ultrasonic (LU10-_305 or LU10-_325) Wire
Configuration:

Buoyancy (LV10-_301 or LV10-_351) Wire
Configuration:

Compact

Relay Controller

(inside shown)

Summary of Contents for Switch Pak A*13 series

Page 1: ...here is evidence of a potentially hazardous material present with product b The product has remained unclaimed at Flowline for longer than 30 days after dutifully requesting disposition of the product THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS WARRANTY This warranty and the obligations and liabilities of Flowline under it are exclusive and instead of and the or...

Page 2: ...0 psi 10 bar AV13 25 psi 1 7 bar Wetted material 42__ PP 52__ PVDF Kynar Process mount _2_3 2 NPT _2_7 1 1 2 G Enclosure rating NEMA 4X IP65 Installed height _21_ 6 5 16 5 cm _22_ 4 9 12 4 cm Encl material _21_ PP UL94VO and polycarbonate _22_ PP UL94VO Conduit entrance Single 1 2 NPT Classification General purpose CE compliance EN 50082 2 immunity EN 55011 emission EN 61010 1 safety Sensor Techno...

Page 3: ...evel Switch P N LU10 1305 LU10 1325 LU10 2305 LU10 2325 LV10 1301 LV10 1351 LV10 5301 LV10 5351 or LZ12 1405 A Specify Ultrasonic AU13 4223 1 x LU10 1305 1 x LM45 1001 1 x LC10 1001 AU13 4227 1 x LU10 1325 1 x LM45 1061 1 x LC10 1051 AU13 5223 1 x LU10 2305 1 x LM45 5001 1 x LC10 1001 AU13 5227 1 x LU10 2325 1 x LM45 5061 1 x LC10 1051 Buoyancy AV13 4223 1 x LV10 1301 1 x LM45 1001 1 x LC10 1001 A...

Page 4: ...al wiring of any liquid level control system should be performed in accordance with all applic able national state and local codes Take care not to cut or break the outer insulation jacket of wiring that may be immersed while routing cables in the Switch Pak system Such breaks of the liq uid seal of the sensor system may lead to component failure Flammable Explosive and Hazardous Applications The ...

Page 5: ...overed in the Installation section of the LC10 11 Series Manual Polarity neu tral and hot does not matter 4 Relay terminals NC C NO Connect the device you wish to control pump alarm etc to these terminals supply to the COM terminal and the device to the NO or NC terminal as required The switched device should be a noninductive load of not more than 10 amps for reactive loads the current must be de...

Page 6: ... is completely disconnected 2 Sensor Removal Make sure that the tank is in a state where it is safe to remove the sensors Carefully remove the Switch Pak from the installation 3 Cleaning the Sensor Use a soft bristle brush and mild deter gent carefully wash the Switch Pak Do not use harsh abra sives such as steel wool or sandpaper which might damage the surface sensor Do not use incompatible solve...

Reviews: