IMPORTANT MOUNTING GUIDELINES 
 

1)  Never mount the transmitter at an angle. 
2)  Liquid should never enter the dead band. 
3)  Mount at least 3” from the side wall. 
4)  Never mount the transmitter in a vacuum. 
5)  Do not obstruct the transmitter’s beam width with objects underneath the transmitter. 
6)  Never mount in the center of a  dome top tank. 
7)  In a cone bottom tank, position the transmitter over the deepest part of the tank. 
8)  Avoid mounting in a riser where the transmitter is recessed more than twice the diameter of the riser. 

 

MOUNTING IN A STAND-PIPE

 

 
A stand-pipe may be used to dampen turbulence, separate surface foam from the point of measurement or 
increase performance in heavy vapor.  When mounting the transmitter in a stand-pipe, the minimum diameter of 
the pipe is 2” for the US01 and US03 series and 3” for the US06 series.  Larger diameter pipes can be used.  
The pipe should be attached with a coupling or tank adapter and reducer bushing.  Avoid the use of multiple pipe 
fittings when possible.  An ideal mount would be to select a 3” tank adapter (S x T or S x S) and connect the pipe 
to the inside slip and use a reducer bushing to attach the transmitter (see example below).   
 
The pipe length should run the measurement span and the bottom of the pipe should remain submerged at all 
times to prevent foam from entering the pipe.  Cut the bottom end of the pipe at 45° and drill a 1/4” pressure 
equalization hole within the transmitter’s dead band.  Locate the stand-pipe away from pump outlets and/or other 
sources of substantial turbulence which might cause the liquid in the pipe to oscillate.  

 
3” x 2”  
Reducer Bushing 
(TxT) 
 
3” Tank  
Adapter  
(S x T) 
 
 
 
3” PVC Pipe 

 

 
Stand-Pipe Example 

 

Stand-Pipe Mounting

 

 

 

 

Summary of Contents for EchoPod UG06-12

Page 1: ...Alamitos CA 90720 p 562 598 3015 f 562 431 8507 w flowline com QS300820 Rev A2 2018 Flowline Inc All Rights Reserved Made in USA US01 US03 US06 Series Quick Start EchoTouch Intrinsically Safe Reflecti...

Page 2: ...6 0003 01 US06 0013 00 US06 0013 01 USB Key Fob P N LI99 2001 Viton gasket 2 P N 200129 G threaded version only WebCal Configuration Only WebCal Configuration Only Push Button or WebCal Configuration...

Page 3: ...om o H WEBCAL hrough Web ting since it SOFTWARE re from www 8 10 10 MB ternet conne eeding to Ste B FOB Fob to your e sensor to t the software ect the displ tes to WebC xternal powe ch is 15 d unplug...

Page 4: ...an It is based o n for the sen s based on t e below ndition for the t of liquid in sor Height an nits shown u nd Fill Heigh on the distan nsor bottom the distance e transmitte Loop Fail o Sets t the t...

Page 5: ...ration and saves the configuration file to your hard drive Before configuration can be completed You must click the Write to Unit button to save the settings to the unit Then click Wiring Diagram for...

Page 6: ...RE THE TANK Measuring the tank is one of the most important aspects in configuring the transmitter When measuring the tank take into account the location of the transmitter with respect to fittings ri...

Page 7: ...EXIT by pressing OK to return to the TOP LEVEL MENU 9 Select RUN by pressing OK to return to Operational Mode Note The Height 4mA and Fill Height 20mA settings also determine the 4 to 20 mA current s...

Page 8: ...such as the LM52 2400 3 to 2 Use a flange with a 2 thread such as the LM52 2850 Weld a plastic 2 half coupling to the tank top Mounting in Riser Installations with tall narrow risers can impede the a...

Page 9: ...e minimum diameter of the pipe is 2 for the US01 and US03 series and 3 for the US06 series Larger diameter pipes can be used The pipe should be attached with a coupling or tank adapter and reducer bus...

Page 10: ...upply to the input and to sense the current flow out of the output For all Intrinsically Safe applications refer to control drawing 600820 for the US06 series and 610125 for the US01 and US03 series A...

Page 11: ...tible with the application Design a fail safe system for possible transmitter and or power failure When used as an intrinsically safe device always refer to control drawing 600820 for the US06 series...

Page 12: ...2 have been subjected to electrical mechanical or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personnel authorized by Flowl...

Reviews: