FlowLine EchoPod UG06-12 Quick Start Manual Download Page 2

|

   2

 

QS300820 Rev A2 

WELCOME TO THE ECHOTOUCH

®

 QUICK START 

The EchoTouch

®

 Quick Start provides basic mounting, setup and use instructions for getting the 

EchoTouch

®

 up and running quickly.  If you have a non-standard installation or setup requirement that is 

not addressed here, please refer to the EchoTouch

®

 Manual or other support documentation located at 

flowline.com. 

 
WE DO YOUR LEVEL BEST 

 
Thank you for purchasing EchoTouch

®

.  The transmitter provides WebCal

®

 software configuration (all models) 

or integrated LCD and three push-button configuration (US06 series only).  This quick start includes everything 
you’ll need to get the transmitter up and running.   
 

COMPONENTS 

 
Depending upon the transmitter part number shipped, EchoTouch

®

 comes with the Quick Start and a Viton

®

 

gasket for installation with G threaded versions only. 

 

 

 

EchoTouch

®

 

US01-0001-00 
US01-0001-01 
US01-0011-00 
US01-0011-01 

EchoTouch

®

 

US03-0001-00 
US03-0001-01 
US03-0011-00 
US03-0011-01 

EchoTouch

®

 

US06-0003-00 
US06-0003-01 
US06-0013-00 
US06-0013-01 

USB

®

 Key Fob 

P/N: LI99-2001 

Viton

®

 gasket (2”) 

P/N:  200129 

G threaded version 

only 

WebCal 

Configuration Only 

WebCal 

Configuration Only 

Push Button or 

WebCal 

Configuration 

 

 

 

ENCLOSURE 

 
While the enclosure housing is liquid-resistant the EchoTouch

®

 transmitter is not designed to be operational 

upon being immersed.  It should be mounted in such a way that the enclosure and transducer do not come into 
contact with the application media under normal operational conditions.   Before closing the enclosure (US06 
series only), make sure that the enclosure gasket is properly seated, and that any conduit fittings, cable 
connectors or plugs are installed correctly and sealed.  

Note:

 If using the Flowline LM90-1001 (liquid tight 

fitting) on the ½” conduit, the cable minimum is 0.170” (4.3mm) and the maximum is 0.450” (11.4mm). 
 

CONFIGURATION 

 
When configuring EchoTouch

®

, choose either the WebCal

®

 (all versions of EchoTouch

®

) or Push Button 

method (US06 series only).  Changes to the configuration can be made using the alternative method.  When 
beginning with one method, it is recommended to complete the configuration before using the other method to 
make any adjustments. 

 

 

Summary of Contents for EchoPod UG06-12

Page 1: ...Alamitos CA 90720 p 562 598 3015 f 562 431 8507 w flowline com QS300820 Rev A2 2018 Flowline Inc All Rights Reserved Made in USA US01 US03 US06 Series Quick Start EchoTouch Intrinsically Safe Reflecti...

Page 2: ...6 0003 01 US06 0013 00 US06 0013 01 USB Key Fob P N LI99 2001 Viton gasket 2 P N 200129 G threaded version only WebCal Configuration Only WebCal Configuration Only Push Button or WebCal Configuration...

Page 3: ...om o H WEBCAL hrough Web ting since it SOFTWARE re from www 8 10 10 MB ternet conne eeding to Ste B FOB Fob to your e sensor to t the software ect the displ tes to WebC xternal powe ch is 15 d unplug...

Page 4: ...an It is based o n for the sen s based on t e below ndition for the t of liquid in sor Height an nits shown u nd Fill Heigh on the distan nsor bottom the distance e transmitte Loop Fail o Sets t the t...

Page 5: ...ration and saves the configuration file to your hard drive Before configuration can be completed You must click the Write to Unit button to save the settings to the unit Then click Wiring Diagram for...

Page 6: ...RE THE TANK Measuring the tank is one of the most important aspects in configuring the transmitter When measuring the tank take into account the location of the transmitter with respect to fittings ri...

Page 7: ...EXIT by pressing OK to return to the TOP LEVEL MENU 9 Select RUN by pressing OK to return to Operational Mode Note The Height 4mA and Fill Height 20mA settings also determine the 4 to 20 mA current s...

Page 8: ...such as the LM52 2400 3 to 2 Use a flange with a 2 thread such as the LM52 2850 Weld a plastic 2 half coupling to the tank top Mounting in Riser Installations with tall narrow risers can impede the a...

Page 9: ...e minimum diameter of the pipe is 2 for the US01 and US03 series and 3 for the US06 series Larger diameter pipes can be used The pipe should be attached with a coupling or tank adapter and reducer bus...

Page 10: ...upply to the input and to sense the current flow out of the output For all Intrinsically Safe applications refer to control drawing 600820 for the US06 series and 610125 for the US01 and US03 series A...

Page 11: ...tible with the application Design a fail safe system for possible transmitter and or power failure When used as an intrinsically safe device always refer to control drawing 600820 for the US06 series...

Page 12: ...2 have been subjected to electrical mechanical or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personnel authorized by Flowl...

Reviews: