www.flowair.com |7
3. CAPACITEITSGEGEVENS
3. HEAT OUTPUT DATA
3.1. ELIS DUO-W-100
V
– luchthoeveelheid
PT
- verwarmingscapaciteit
Tp1
- aanzuigluchttemperatuur
T
p2
- uitlaatluchttemperatuur
Tw1
- inlaatwatertemperatuur
Tw2
- uitlaatwatertemperatuur
Qw
- waterstroming in de warmtewisselaar
Δpw
- waterdrukval in de warmtewisselaar
V
– air flow
PT
– heating capacity
Tp1
– inlet air temperature
T
p2
– outlet air temperature
Tw1
– inlet water temperature
Tw2
– outlet water temperature
Qw
– heating water stream
Δpw
– water pressure
Luchtgordijn / Air curtain
PT
Qw
Δpw
Tp2
PT
Qw
Δpw
Tp2
Tp1
V
kW
l/h
kPa
°C
kW
l/h
kPa
°C
°C
m
3
/h
Tw1 / Tw2 = 90/70
o
C
Tw1 / Tw2 = 80/60
o
C
0
800/
1100/
1400
11,6/14,3/16,5
max.1095
max.11,9
43/38/35
9,9/12,2/14,2
max.936
max.9,2
37/33/30
5
10,9/13,3/15,5
45/41/38
9,2/11,3/13,1
39/36/33
10
10,1/12,5/14,5
47/43/40
8,5/10,4/12,0
41/38/35
15
9,4/11,5/13,4
49/46/43
7,7/9,5/11,0
43/40/38
20
8,7/10,7/12,3
52/48/46
7,0/8,6/9,9
46/43/41
Tw1 / Tw2 = 70/50
o
C
Tw1 / Tw2 = 70/40
o
C
0
800/
1100/
1400
8,3/10,2/11,9
Max. 778
max.6,7
31/27/25
6,9/8,5/9,8
max.429
max.2,3
26/23/21
5
7,6/9,3/10,8
33/30/28
6,1/7,6/8,7
28/25/24
10
6,8/8,4/9,7
35/32/30
5,3/6,5/7,6
30/28/26
15
6,0/7,5/8,7
37/35/33
4,5/5,5/6,5
31/30/29
20
5,3/6,5/7,5
39/37/36
3,6/4,5/5,3
33/32/31
Tw1 / Tw2 = 60/40
o
C
Tw1 / Tw2 = 50/40
o
C
0
800/
1100/
1400
6,7/8,1/9,5
max.620
max.4,6
25/22/20
6,4/7,9/9,1
max.1194
max.15,4
24/21/19
5
5,7/7,3/8,4
27/24/23
5,7/6,9/8,0
26/24/22
10
5,1/6,3/7,3
29/27/25
4,9/6,0/7,0
28/26/25
15
4,3/5,3/6,2
31/29/28
4,1/5,0/5,9
30/29/27
20
3,5/4,3/5,0
33/32/31
3,4/4,1/4,8
32/31/30
Luchtverwarmer / Fan heater
PT
Qw
Δpw
Tp2
PT
Qw
Δpw
Tp2
Tp1
V
kW
l/h
kPa
°C
kW
l/h
kPa
°C
°C
m
3
/h
Tw1 / Tw2 = 90/70
o
C
Tw1 / Tw2 = 80/60
o
C
0
400/
550/
700
5,8/7,2/8,3
max.1095
max.11,9
43/38/35
5,0/6,1/7,1
max.936
max.9,2
37/33/30
5
5,5/6,7/7,8
45/41/38
4,6/5,7/6,6
39/36/33
10
5,1/6,3/7,3
47/43/40
4,3/5,2/6,0
41/38/35
15
4,7/5,8/6,7
49/46/43
3,9/4,8/5,5
43/40/38
20
4,4/5,4/6,2
52/48/46
3,5/4,3/5,0
46/43/41
Tw1 / Tw2 = 70/50
o
C
Tw1 / Tw2 = 70/40
o
C
0
400/
550/
700
4,2/5,1/6,0
max.778
max.6,7
31/27/25
3,5/4,3/4,9
max.429
max.2,3
26/23/21
5
3,8/4,7/5,4
33/30/28
3,1/3,8/4,4
28/25/24
10
3,4/4,2/4,9
35/32/30
2,7/3,3/3,8
30/28/26
15
3,0/3,8/4,4
37/35/33
2,3/2,8/3,3
31/30/29
20
2,7/3,3/3,8
39/37/36
1,8/2,3/2,7
33/32/31
Tw1 / Tw2 = 60/40
o
C
Tw1 / Tw2 = 50/40
o
C
0
400/
550/
700
3,4/4,1/4,8
max.620
max.4,6
25/22/20
3,2/4,0/4,6
max.1194
max.15,4
24/21/19
5
2,9/3,7/4,2
27/24/23
2,9/3,5/4,0
26/24/22
10
2,6/3,2/3,7
29/27/25
2,5/3,0/3,5
28/26/25
15
2,2/2,7/3,1
31/29/28
2,1//2,5/3,0
30/29/27
20
1,8/2,2/2,5
33/32/31
1,7/2,1/2,4
32/31/30
Summary of Contents for ELIS G W 200