Table Of Contents 

1.  GENERAL  INFORMATION ........................................................ 3 
2.  TECHNICAL DATA ..................................................................... 3 

2.1. CONSTRUCTION ................................................................. 3 
2.2. DIMENSIONS ....................................................................... 4 
2.3. ACOUSTIC PRESSURE LEVEL ........................................... 4 
2.4. AIR VOLUME ........................................................................ 4 
2.5. NOMOGRAM OF AIR FLOW SPEED ................................... 5 

3.  HEAT OUTPUT DATA ................................................................ 5 

3.1.  ELIS A-W-100 ..................................................................... 5 
3.2.  ELIS A-W-150 ..................................................................... 6 
3.1. ELIS A-W-200 ....................................................................... 6 

4.  INSTALLATION ........................................................................... 7 

4.1. RECOMMENDATION OF MONTAGE DISTANCES .............. 7 
4.2. MOUNTING BY RODS UNDER THE CEILING ..................... 7 
4.3. MOUNTING ON THE WALLS BY THE BRACKETS .............. 8 
4.4. BRACKETS .......................................................................... 8 
4.5. STAGES OF INSTALATION ................................................. 9 

5.  CONTROL  SYSTEMS .............................................................. 10 

5.1. CONTROL ELEMENTS ...................................................... 10 
5.2 CONNECTING GUIDE ........................................................ 11 
5.3. CONTROL SYSTEM ........................................................... 11 

5.3.1.   REGULATION TS 

– ELIS A-W/N WIRING 

DIAGRAMS ............................................................ 12 

5.3.2 REGULATION TS 

– ELIS A-E WIRING DIAGRAMS 12 

5.3.3 REGULATION T-box - ELIS A-W/N WIRING 

DIAGRAMS ............................................................ 13 

5.3.4 REGULATION T-box - ELIS A-E WIRING DIAGRAMS

 

………………………………………………………..13 

5.3.5 CONTROL SYSTEM 

– MASTER-SLAVE 

COMMUNICATION ................................................ 14 

5.3.6  CONTROL SYSTEM 

–  BMS CONNECTION ......... 14 

5.3.7. CONTROL SYSTEM 

–  SETTING BMS ADDRESS 14 

5.3.8. DRV CONTROL SYSTEM 

–  BMS REGISTERS .... 15 

5.4. DOOR CONTACT INSTALLATION ..................................... 16 

6. GUIDELINES FOR CONNECTION WITH POWER SUPPLY ....... 16 
7.  GUIDELINES FOR CONNECTION WITH PIPELINE .................. 16 
8.  OPERATION ............................................................................. 16 
9.  FILTERS REPLACEMENT ........................................................ 17 
10.  CLEANING AND CONSERVATION .......................................... 17 
11.  SERVICE .................................................................................. 17 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Thank  you  for  purchasing  the  ELiS  curtain.  This  operation 
manual  has  been  issued  by  the  FLOWAIR  GŁOGOWSKI 

BRZEZIŃSKI SP.J. company. The manufacturer reserves the 

right to make revisions and changes in the operation manual at 
any time and without notice, and also to make changes in the 
device without influencing its operation 

This  manual  is  an  integral  part  of  the  device  and  it  must  be 
delivered  to  the  user  together  with  the  device.  In  order  to 
ensure  correct  operation  of  the  equipment,  get  thoroughly 
acquainted with this manual and keep it for the  future. 

The  devices  may  only  be  installed  and  operated  in  conditions 
for  which  they  have  been  designed.  Any  other  application, 
inconsistent  with  this  manual,  may  lead  to  the  occurrence  of 
accidents with dangerous consequences. Every effort must be 
made in order to eliminate the possibility of improper use of the 
device.  Access  of  unauthorized  persons  to  the  device  should 
be  restricted,  and  the  operating  personnel  should  be  trained. 
The manufacturer bears no responsibility for damage resulting 
from  incorrect  installation,  improper  operating,  or  not  getting 
acquainted with the guidelines of the manufacturer manual. 

RECOMMENDATIONS AND REQUIRED SAFETY 
MEASURES

 

  Get  acquainted  with  this  operation  manual  before 

performing any works at the device. 

  The  device  may  only  be  installed  by  qualified  personnel 

with adequate authorisations and skills. 

  In the building where ventilation causes underpressure, air 

cutrain may have limited efficiency 

  When  performing  works  at  the  device,  remember  about 

your own safety. 

  During  installation,  electrical  connection,  connection  to  the 

heating  medium,  start-up,  repairs  and  maintenance  of  air 
curtains,  observe  the  commonly  recognized  safety 
standards and regulations. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ELIS A-E-100

Page 1: ...TECHNICAL DOCUMENTATION OPERATION MANUAL DTR ELIS A 4 0 2015 10 22 PL ...

Page 2: ...in the operation manual at any time and without notice and also to make changes in the device without influencing its operation This manual is an integral part of the device and it must be delivered to the user together with the device In order to ensure correct operation of the equipment get thoroughly acquainted with this manual and keep it for the future The devices may only be installed and op...

Page 3: ...HNICAL DATA A W 100 A N 100 A E 100 A W 150 A N 150 A E 150 A W 200 A N 200 A E 200 Power supply V Hz 230 50 3x400 50 230 50 3x400 50 230 50 3x400 50 Power consumption kW 0 17 7 0 25 10 7 0 34 15 Current consumption A 0 72 10 1 1 15 5 1 45 21 5 IP Insulation class 21 F Connecting stub Max water temperature o C 95 95 95 Max water pressure MPa 1 6 1 6 1 6 1 6 Temperature increase T ºC 34 25 25 21 24...

Page 4: ...0 A N 200 A E 200 3 50dB A 53dB A 55dB A 2 43dB A 46dB A 48dB A 1 39dB A 42dB A 44dB A Acoustic pressure level measured in the room of average sound absorption capacity 500m3 at the distance of 3 m apart of the unit 2 4 AIR VOLUME step A W 100 A N 100 A E 100 A W 150 A N 150 A E 150 A W 200 A N 200 A E 200 3 1500m 3 h 2500 m 3 h 3500 m 3 h 2 1150m 3 h 2100 m 3 h 2900 m 3 h 1 800m 3 h 1650 m 3 h 24...

Page 5: ... 9 218 268 319 0 7 1 0 1 4 30 28 26 10 8 3 10 1 12 0 361 443 526 1 7 2 4 3 3 38 35 33 6 4 7 9 9 4 186 230 274 0 5 0 8 1 1 31 30 28 15 7 2 8 9 10 5 316 388 461 1 3 1 9 2 6 40 37 35 5 2 6 6 7 9 153 191 229 0 4 0 6 0 8 33 32 30 20 6 2 7 6 9 1 271 334 397 1 0 1 5 2 0 42 40 38 3 9 5 1 6 3 114 150 182 0 2 0 4 0 5 34 33 32 Tw1 Tw2 60 40 o C Tw1 Tw2 50 40 o C 0 850 1150 1500 8 3 10 1 12 0 360 442 525 1 8 ...

Page 6: ...A W 200 PT Qw Δpw Tp2 PT Qw Δpw Tp2 Tp1 V kW l h kPa C kW l h kPa C C m 3 h Tw1 Tw2 90 70 o C Tw1 Tw2 80 60 o C 0 2400 2900 3500 25 7 29 32 2 1135 1271 1419 12 14 5 18 32 29 27 22 24 7 27 6 970 1086 1212 9 11 1 13 6 27 25 23 5 24 27 30 1063 1191 1329 10 4 13 16 35 32 30 20 4 22 9 25 5 898 1006 1122 7 8 9 7 11 8 30 28 27 10 22 5 25 1 28 992 1110 1240 9 2 11 3 14 38 36 34 18 8 21 23 5 825 924 1031 6...

Page 7: ...e by side While mounting ELiS A side by side it is important to start from right side like is shown below all electrical conntection should be done before installing following curtain 4 1 RECOMMENDATION OF MONTAGE DISTANCES 4 2 MOUNTING BY RODS UNDER THE CEILING While mounting curtains under the ceiling 4 rods M8 should be screwed minimum 20 mm deep ...

Page 8: ...LS BY THE BRACKETS ELIS A W 100 A N 100 A E 100 A W 150 A N 150 A E 150 A W 200 A N 200 A E 200 4 4 BRACKETS Brackets ELiS A 2 x bracket ELiS A 4 x plug Ø10 4 x double threaded screw M8 4 x washer M8 4 x nut M8 4 x allen screw M8 not included ...

Page 9: ...r com 9 4 5 STAGES OF INSTALATION Curtain Type Distance between brackets mm ELiS A W 100 ELiS A E 100 ELiS A N 100 970 ELiS A W 150 ELiS A E 150 ELiS A N 150 1440 ELiS A W 200 ELiS A E 200 ELiS A N 200 1895 1 2 3 ...

Page 10: ...m mechanical door contact Operating temperature range 10 80 o C IP Insulation class IP 65 Connectors 1xNC i 1xNO Max current resistive 10A inductive 3A Max Power load 300Vac or 250Vdc DCe magnetic door contact Operating temperature range 5 60 o C IP Insulation class IP 64 Connectors NC Max current inductive resistive 0 5A Max power Load 175Vdc Lenght of cabel 2m Max operating contactors distance 8...

Page 11: ...ed operating S1 S2 S3 signalize number of set fan speed T signalize of valve set DC signalize of door contact set OPEN CLOSE signalize valve actuator WORK signalize of software working SW3 operating mode switch default settings 1 Device function selection BMS Address adjustment 2 MASTER mode operating SLAVE mode operating 3 Curtain Heater DUO 4 ELiS W N ELiS E 5 K1 Programme K2 Programme 6 Operati...

Page 12: ...y B Return pipe water supply 5 3 2 REGULATION TS ELIS A E WIRING DIAGRAMS Power supply 3x400V 50Hz ELiS A E 100 min 5x4 mm2 Overcurrent B16 ELiS A E 150 min 5x6 mm2 Overcurrent B20 ELiS A E 200 min 5x6 mm2 Overcurrent B25 Air curtain step switch with thermostat TS OMY 5x0 5mm 2 HEAT heating mode FAN room thermostat deactivated COOL cooling mode Door contact DCe DCm door closed contacts opened door...

Page 13: ...y B Return pipe water supply 5 3 4 REGULATION T box ELIS A E WIRING DIAGRAMS Power supply 3x400V 50Hz ELiS A E 100 min 5x4 mm2 Overcurrent B16 ELiS A E 150 min 5x6 mm2 Overcurrent B20 ELiS A E 200 min 5x6 mm2 Overcurrent B25 T box OMY 4x0 5mm 2 Door contact DCe DCm door closed contacts opened door opened contacts closed ATTENTION Switch 4 on SW3 to the position E and then restart the system switch...

Page 14: ...LAVE curtain 5 3 6 CONTROL SYSTEM BMS CONNECTION DRV driver has a possibility to be connected to integrated Building Management System BMS Parameters Name Description Physical layer RS485 Protocol MODBUS RTU Baud rate 38400 bps Parity Even Data bits 8 STOP bits 1 Connection must be made using 3 poliges wire to connectors IN A IN B GND SIGNAL GROUND UWAGA Dla ostatniego urządzenia pracującego w sie...

Page 15: ...ermostat is off 1 HEAT_ON Curtain s thermostat is on 5 0x08 ContactDoor 0 1 Set value for door contact 0 DOOR_CLOSE Door is closed 1 DOOR_OPEN Door is opend Inputs Register Data write Lp Adres rejestru Nazwa parametru Min Max Opis 1 0x04 CurtainFanSpeed 0 3 Curent fan step 0 FAN_SPEED0 Fan is off 1 FAN_SPEED1 1st step of fan is on 2 FAN_SPEED2 2nd step of fan is on 3 FAN_SPEED3 3rd step of fan is ...

Page 16: ... should be executed so that in the case of a failure it is possible to disassemble the device For this purpose it is best to use shut off valves just by the device The system with the heating medium must be protected against an increase of the heating medium pressure above the permissible value 1 6 MPa While screwing exchanger to pipeline connecting stubs has to be hold by wrench 8 OPERATION The d...

Page 17: ...ount inlet grill guard It is recommended to use pressured air to clean the exchanger air stream need to be directed perpendicular to exchanger and moved along lamellas It is prohibited to use water or sharp items to clean exchanger Other installed equipment do not need be cleaned 11 SERVICE In the case of any irregularities in the device operation please contact the manufacturer s service departme...

Page 18: ...tu product launch date 2014 jest zgodna z zasadniczymi wymaganiami was produced in accordance to the following European Directives dyrektywy directives MD 2006 42 WE dyrektywy directives EMC 2004 108 WE oraz zharmonizowanymi z tymi dyrektywami normami and harmonized norms with above directives PN EN 60204 1 2010 Bezpieczeństwo maszyn Wyposażenie elektryczne maszyn Część 1 Wymagania ogólne Safety o...

Page 19: ...h mieszkalnym handlowym i lekko uprzemysłowionym Electromagnetic compatibility EMC Part 6 1 Generic standards Immunity for residential commercial and light industrial environments PN EN 61000 6 2 2008 Kompatybilność elektromagnetyczna EMC Część 6 2 Normy ogólne Odporność w środowiskach przemysłowych Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environments P...

Reviews: