8. Place the end cap vertically on a work bench with
the check valve end up.
9. Remove the check valve assembly from the end cap
by using two screwdrivers in the circumferential
groove in the OD of the check valve body. Be care-
ful not to damage the body or the end cap. Remove
the o-ring from the check valve assembly.
10. Place the check valve body in the provided
rebuild clamp.
Note
: Do not cover the holes on the outer circum-
ference of the check valve body to prevent metal
from being introduced into the opening.
11. Loosen the outlet cage.
12. Remove the outlet poppet and guide, outlet poppet
spring, and outlet poppet seat from the outlet cage.
Retain the cage. Discard the outlet poppet and
guide, outlet poppet spring, outlet poppet seat, and
check valve body.
© Flow International Corporation
M-416 | 69
CHAPTER 4
Service
Summary of Contents for HYPLEX
Page 1: ...HYPLEX PRIME PUMP M 416 REV C MAY 2012 ...
Page 7: ... Flow International Corporation M 416 7 CHAPTER 1 Equipment Description ...
Page 8: ...8 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 9: ... Flow International Corporation M 416 9 CHAPTER 1 Equipment Description ...
Page 18: ...Notes 18 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 33: ... Flow International Corporation M 416 33 CHAPTER 3 Maintenance Troubleshooting ...
Page 40: ...Notes 40 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 66: ...Notes 66 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 78: ...Notes 78 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 82: ...Notes 82 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 94: ...Notes 94 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 100: ...Notes 100 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...