Install the manifold assembly
1. Apply a thin coat of Blue Lubricant to each of the
threads on the 3/8 in. high-pressure glands.
2. Slide tube shielding over the tube length.
3. On each end of the tube: slide a gland on to the
tube, then thread a collet and a collar on the
threaded end of the tube.
4. Repeat Steps 1
-
3 for the remaining two high-pres-
sure tubes.
5. Insert one end of the tube into the high-pressure
port on the manifold and loosely thread the glands
in place. Repeat for the other high-pressure tubes.
6. Loosely thread the other end of each of the three
tubes into the end cap ports.
7. Once in place, tighten all six gland nuts. Torque to
40 ft-lb (54 N-m).
8. Reconnect all high- and low-pressure interface con-
nections
64 | M-416
© Flow International Corporation
HYPLEX PRIME PUMP
Maintenance & Service Manual
Summary of Contents for HYPLEX
Page 1: ...HYPLEX PRIME PUMP M 416 REV C MAY 2012 ...
Page 7: ... Flow International Corporation M 416 7 CHAPTER 1 Equipment Description ...
Page 8: ...8 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 9: ... Flow International Corporation M 416 9 CHAPTER 1 Equipment Description ...
Page 18: ...Notes 18 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 33: ... Flow International Corporation M 416 33 CHAPTER 3 Maintenance Troubleshooting ...
Page 40: ...Notes 40 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 66: ...Notes 66 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 78: ...Notes 78 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 82: ...Notes 82 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 94: ...Notes 94 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 100: ...Notes 100 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...