30 | M-416
© Flow International Corporation
HYPLEX PRIME PUMP
Maintenance & Service Manual
FlowSENSE diagnostic codes
FlowSENSE is only available for the Premium package.
The tables below list all shutdown and warning codes for the HyPlex Prime that may appear on the system display (or
console display if a standalone pump). Likely causes and possible solutions to those causes are included after each
code description.
FlowSENSE shutdown codes
27203 Low inlet water pressure shutdown
•
Water supply valve(s) closed
•
Inlet water pressure low (< 15 psi [1.03 bar])
•
Dirty water filters
Check the water supply cut off, and make sure the water supply valve (when
supplied) is in the correct position. Remove and check the water filter car-
tridges; replace if dirty.
Faulty cable coming from the multi-port box
Inspect the cable assembly at the multi-port box. Replace if necessary.
27206 Motor overload shutdown
Overload setting is lower than specified in the
electrical schematic drawing.
Call Flow Technical Service.
27201 Pump is in E-Stop condition shutdown
Machine (M4c or M2c) is in E-stop condition
Follow proper E-stop reset procedure (M4c or M2c).
Problem with safety network
Call Flow Technical Service.
27202 Motor starter shutdown
Main circuit breaker has tripped
Reset circuit breaker.
•
Faulty soft starter
•
Faulty isolation contactor
Call Flow Technical Service.
FlowSense warning codes
27255 Inlet water high temperature warning
•
Water inlet above 70°F (21°C)
•
Dynamic seal(s) may be damaged
Check inlet water temperature to make sure it is below 70°F.
Install a Minor Maintenance Kit.
Faulty cable coming from the multi-port box
Inspect the cable assembly at the multi-port box. Refer to electrical sche-
matic. Replace if necessary.
27257 Analog input out of range warning
Thermistor cables disconnected
Make sure the cables are connected.
Faulty thermistor(s)
Run the Temperature Input Offset Adjustment Routine. If warning persists,
replace thermistors if suspected.
Faulty analog input module
Call Flow Technical Service.
Faulty pump health board
Summary of Contents for HYPLEX
Page 1: ...HYPLEX PRIME PUMP M 416 REV C MAY 2012 ...
Page 7: ... Flow International Corporation M 416 7 CHAPTER 1 Equipment Description ...
Page 8: ...8 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 9: ... Flow International Corporation M 416 9 CHAPTER 1 Equipment Description ...
Page 18: ...Notes 18 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 33: ... Flow International Corporation M 416 33 CHAPTER 3 Maintenance Troubleshooting ...
Page 40: ...Notes 40 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 66: ...Notes 66 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 78: ...Notes 78 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 82: ...Notes 82 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 94: ...Notes 94 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Page 100: ...Notes 100 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...