205289 D/GB
21
GB
1. Operating Modes
1.1
Operating Mode "Setup"
à
Reference point
Use the drilling crosshairs to guide the tool to the workpiece and
to set the actual value for drilling depth to
zero.
à
Feed rate
Use
and
o move the flashing cursor to the digit to be changed. Use
or
to change the value.
à
Setpoint value for drilling depth
Use
and
o move the flashing cursor to the digit to be changed. Use
or
to change the value.
or
Set the reference point. Use the drilling crosshairs to guide the tool to the desired drilling depth. Press
to
accept the displayed "Actual value for drilling depth" into the displayed "Setpoint value for drilling depth".
à
Saving a set of parameters (feed rate and setpoint value for drilling depth)
Pressing
and
simultaneously stores a set of parameters permanently.
Spindle speed
Feed rate
Setpoint value for drilling depth
Actual value for drilling depth