Section 17 - Pulsation Dampers
This section is common to all pumps.
Pulsation dampers are obtainable to be fitted to FPL pumps but vary depending upon the individual
model considered.
The maintenance instructions given below apply to all models, although the mounting of the damper on
to the pump may vary slightly.
MAINTENANCE
Before carrying out any maintenance or servicing, the air system must be isolated and the connections
disconnected from the process line. If integral, turn off air supply at the pump. If separate, disconnect
from the supply located at the side of the spool valve on top of the damper.
DISASSEMBLY
Use an M5 allen key to remove the socket cap screws holding the spool valve in position. This will enable
you to remove the spool valve.
Undo the 16 nuts and bolts around the damper and remove the air dome. This exposes the PTFE
faced diaphragm with spool valve rod attached. Place the rod into a vice fitted with soft jaws and unscrew.
48
Pulsation Dampers
Summary of Contents for F 500 series
Page 15: ...7 Your Notes...
Page 30: ......
Page 35: ......
Page 36: ...30 F Series Good Food Style Pump Section 13 F Series Good Food Style Pump...
Page 38: ......
Page 40: ...35 F Series Slim Style Metallic Pumps Section 14 F Series Slim Style Metallic Pumps...
Page 43: ......
Page 44: ...40 F Series K Style Chemflo All PTFE Section 15 F Series K Style Chemflo All PTFE...
Page 46: ......
Page 48: ...45 Air Valves Section 16 Air Valves...
Page 50: ...47 Pulsation Dampers Section 17 Pulsation Dampers...
Page 54: ...51 Your Notes...
Page 59: ...56 Your Notes...
Page 61: ......
Page 62: ...60 Count Stop Pumps All Series Section 19 Count Stop Pumps All Series...
Page 65: ...63 Your Notes...
Page 67: ...65 Your Notes...
Page 68: ...66 Your Notes...