26
F Series 710 Style
Stainless Steel Pumps
PROCEDURE FOR FITTING DIVIDER SEAL (PTFE)
Divider seals can be fitted into F Series 710 Style pumps with 10” diameter diaphragms. First prise out
the old divider seal from the groove in the centre of the pump body, and refitting, by inserting a new
divider seal up into the inner groove as far as possible by bending the new seal into position.
FIRST, BEND NEW CIRCULAR DIVIDER SEAL AS SHOWN:
Having been fitted, the divider seal should be pushed into place using the handle of a screwdriver or
similar tool, which should not allow damage to occur to the new seal. The thrust tube can then be inserted
as earlier described.
First, bend new circular
divider seal as shown;