Safety 

2

For parts or assistance, call Flotec Customer Service at 1-800-365-6832

Important Safety Instructions

SAVE THESE INSTRUCTIONS

 - This manual contains 

important instructions that should be followed during 
installation, operation, and maintenance of the product. 
Save this manual for future reference.

 This is the safety alert symbol. When you see this 

symbol on your pump or in this manual, look for one of 
the following signal words and be alert to the potential 
for personal injury!

 indicates a hazard which, if not avoided, 

will

 

result in death or serious injury.

 indicates a hazard which, if not avoided, 

could

 result in death or serious injury.

 indicates a hazard which, if not avoided, 

could

 result in minor or moderate injury.

NOTICE

 addresses practices not related to personal injury.

Carefully read and follow all safety instructions in this 
manual and on tank .

1.  Keep safety labels in good condition. Replace 

missing or damaged safety labels.

2.  Consult installer or licensed plumber for correct 

relief valve. Install system according to local codes. 

3.  Always test water from well for purity before using. 

Check local health department for testing procedure.

4.  Before installing or servicing tank, BE SURE pump 

electric power source is disconnected. Release all 
water pressure before working on tank or system. 
Release air pressure before removing cover flange.

5.  Install a relief valve in pump supply line to tank, as 

close to tank as possible.

6.  BE SURE the pump electrical circuit is properly 

grounded.

7.  Remove bleeder orifices, air volume controls or other 

air charging devices in existing system.

8.  DO NOT USE tank as a surge suppressor.

 Hazardous pressure . 

To prevent possible 

serious or fatal injury and/or damage to equipment, 
system pressure must be less than 100 pounds per square 
inch (PSI) (689kPa) under any circumstances. Failure to 
follow instruction can result in tank blowup. If system 
discharge pressure can exceed 100 PSI (689kPa), install 
a relief valve capable of passing the full pump volume at 
100 PSI (689kPa).

Do not allow pump, tank, or piping system to freeze . 
Freezing can severely damage equipment and may lead 
to tank explosion and serious injury . Allowing tank to 
freeze voids tank warranty .

Installation

The tank listed below is pre-charged, or filled with 
air at the factory, to 20 pounds per square inch (PSI) 
(138kPa). When installing tank or if drawdown decreases 
significantly, check as follows:
1.  To check air charge in tank, shut off electric power to 

pump, open faucet near tank, and drain completely.

2.  At air valve, unscrew air valve protective cap and 

check tank air pressure with tire gauge. See Chart 1 
for the correct pressure setting. If needed, adjust the 
tank pressure up or down. To do this, bleed air from 
or add air to tank through valve on top of tank.

3.  Use soap or liquid detergent to check for air leaks 

around air valve. Continuous bubbling indicates 
leak. If necessary, release air pressure and install 
new core in air valve (same as used for automobile 
tubeless tires.)

NOTICE:

 Always set or check tank pre-charge with NO 

WATER in tank and no water pressure in system. If you 
have already pumped water before setting or checking 
the pre-charge pressure, turn the pump off. 

NOTICE:

 Replace and tighten air valve protective cap 

after pressure is adjusted correctly. Failure to replace  
cap may allow loss of air pressure and lead to tank 
waterlogging and diaphragm failure.

Chart I

When Pressure Switch  Setting Is

Adjust Tank Precharge (PSI) To

20-40 PSI (138-276kPa)

18 (124kPa)

30-50 PSI (207-345kPa)

28 (193kPa)

40-60 PSI (276-414kPa)

38 (262kPa)

(The first number on the pressure switch is the 
pump “ON” setting; the second number is the pump 
“OFF” setting.)  
This tank is designed to be supported by the system 
piping either directly above the pump or in a convenient 
location in the piping system as close to the pump 
as possible.

NOTICE:

 Tank capacity is different than drawdown. Tank 

capacity is the actual physical volume of the sheet metal 
that makes up the tank. 

Summary of Contents for FP7105-08

Page 1: ...Installation Operation Parts For further operating installation or maintenance assistance Call 1 800 365 6832 English Pages 2 4 Installation Fonctionnement Pi ces Pour plus de renseignements concerna...

Page 2: ...If system discharge pressure can exceed 100 PSI 689kPa install a relief valve capable of passing the full pump volume at 100 PSI 689kPa Do not allow pump tank or piping system to freeze Freezing can s...

Page 3: ...em with a pre charged tank no bleeder orifices or Air Volume Control AVC are required When sizing a pre charged tank to replace a standard tank the tanks should have equivalent drawdowns Hazardous vol...

Page 4: ...is warranty This warranty does not apply to the following 1 acts of God 2 products which in FLOTEC s sole judgement have been subject to negligence abuse accident misapplication tampering or alteratio...

Page 5: ...ut entra ner l explosion du r servoir Si la pression de refoulement du syst me peut d passer 689 kPa 100 PSI installer un clapet de surpression capable d assurer le plein d bit de la pompe 689 kPa 100...

Page 6: ...charg aucun orifice de purge ou de r gulateur de volume d air n est requis Pour conna tre la dimension d un r servoir pr charg pour remplacer un r servoir standard les r servoirs doivent avoir un sout...

Page 7: ...lles 2 Les produits qui selon FLOTEC ont fait l objet d une n gligence d une utilisation abusive d un accident d une mauvaise application ou d une alt ration 3 Les d faillances dues une installation u...

Page 8: ...100 lib pulg 2 689 kPa instale una v lvula capaz de admitir el caudal pleno de la bomba a 100 lib pulg 2 689 kPa No permita que la bomba el tanque o el sistema de tuber as se congelen El congelamiento...

Page 9: ...uerir n orificios de purga ni Control de Volumen de Aire CVA Cuando determine el tama o del tanque de precarga para reemplazar un tanque est ndar los tanques deber n tener aspiraciones adicionales equ...

Page 10: ...de env o necesarios para reemplazar el producto cubierto por esta garant a Esta garant a no se aplicar en las siguientes situaciones 1 caso de fuerza mayor 2 productos que a s lo juicio de FLOTEC hay...

Page 11: ...Para refacciones o asistencia llame a Flotec Servicios al Cliente al 1 800 365 6832 11...

Page 12: ......

Reviews: