Flotec FP5712 Owner'S Manual Download Page 5

Installation / Operation

5

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

To reduce friction losses to a minimum, inlet (suction)
line should be 

short

and have as few elbows as possible.

Size the inlet according to the chart below:

An inlet strainer will prevent suspended debris from clog-
ging pump. 

The internal running surfaces of the pump and seals
require water lubrication for good, consistent operation.

Allowing pump to run dry will severely damage pump
and seals.

Install a pressure gauge in pump inlet line. Keep at least
two pounds per square inch pressure (2 PSI) in inlet line
whenever pump is operating. If this is not possible, con-
sult customer service representative.

LUBRICATION

It is not necessary to lubricate pump or motor. The motor
is equipped with sealed ball bearings, lubricated for the
life of the bearing. The mechanical shaft seal in the
pump is self-lubricating and requires no adjustment.
Disassemble pump to replace seal (See “Maintenance”,
Pages 8 and 9).

OPERATION

NOTICE:

Observe the following precautions when oper-

ating the pump:

1.

Keep the motor dry! Do not

direct stream from pump

discharge onto the motor!

2.

Hazardous pressure. Do not

run the

pump with discharge shutoff, as hose may burst or
pump may be damaged due to high temperatures.

3.

Do not 

use a standard trigger gun with this pump.

Use only trigger guns with an automatic weeping fea-
ture. These are available as accessories and are  pro-
vided with three nozzles. The smallest nozzle restricts
the flow, allowing use of a smaller water source. The
two larger nozzles are used if the water source will
supply the pump’s full capacity.

4.

Do not

run pump dry; to do so may damage the seal.

5. To avoid internal damage to pump, do not operate

with water temperature above 175 degrees F.

Figure 4 – Wall mounted to pressurized service line.

To Power

Gate Valve or Hose Bibb

Male Pipe to Male Hose Adapter

Male Pipe to Male Hose Adapter

High Pressure Hose with two
Female Connections

Service Line

Male Pipe to Male Hose Adapter

(Suction)

(Discharge)

Female Hose Connection

High Pressure Hose

Gun Nozzle
Weeping Type

 ONLY

1209 0894

Recommended Recommended

Ave.

Threaded

Inlet

Discharge

GPM

Inlet Size

Line Size

Line Size

10

3/4” NPT

1”

1”

Summary of Contents for FP5712

Page 1: ...s Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 11 19 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcio...

Page 2: ...harge pressure does not exceed the pressure rating of hose and fittings See Table I for pump discharge pressure ratings 4 Burn Hazard Never run the pump dry To do so can damage internal parts overheat...

Page 3: ...roducts which in the sole judgement of FLOTEC have been sub ject to negligence abuse accident misapplication tampering alteration nor due to improper installation operation maintenance or storage nor...

Page 4: ...ump body may explode if pressures exceed rated limits Maximum inlet pressure is 80 PSI Maximum discharge pressure is 315 PSI Warranty is void if these pressure limits are exceeded HIGH PRESSURE BOOSTE...

Page 5: ...ICE Observe the following precautions when oper ating the pump 1 Keep the motor dry Do not direct stream from pump discharge onto the motor 2 Hazardous pressure Do not run the pump with discharge shut...

Page 6: ...r 230 volts If necessary reconnect the motor for 115 volts as shown Do not alter the wiring in single voltage motors Install ground wire and maintain your pump in com liance with the National Electric...

Page 7: ...ode 1 Connect ground wire first Connect the ground first then to green grounding terminal provided under motor canopy see Figure 5 identified as GRD Make ground connection to this terminal Do not conn...

Page 8: ...3 Unscrew capacitor clamp and remove capacitor Do not disconnect capacitor wires Slide 7 16 open end wrench in behind spring loaded centrifugal switch as shown Place on motor shaft flats to hold shaft...

Page 9: ...r polished face of seat and press into seal cavity using a 3 4 sock et or a piece of 3 4 standard pipe D Be sure polished surface of seat is free of dirt and has not been damaged by insertion Remove e...

Page 10: ...ater Slinger 1 17351 0009 17351 0009 17351 0009 4 Pump Body 1 C2 85 C2 85 C2 85 5 O Ring 2 U9 430 U9 430 U9 430 6 Shaft Seal Assembly 1 U9 118 U9 118 U9 118 7 Pump Stack 1 P325 425 P325 426 P325 439 7...

Page 11: ...ssions nominales de refoulement de la pompe 4 Risque de br lures Ne jamais faire fonction ner la pompe sec sinon ses pi ces internes seront endommag es la pompe surchauffera et les personnes qui manip...

Page 12: ...dition n cessaires au remplacement du produit couvert par la garantie Cette garantie ne couvrira pas les cas de force majeure et ne s appliquera pas aux produits qui du seul avis de FLOTEC ont fait l...

Page 13: ...de 2 172 kPa 315 lb po2 La garantie sera annul e si ces pressions limites sont d pass es INSTRUCTIONS POUR L INSTALLATION D UNE POMPE DE SURPRESSION HAUTE PRESSION Ces instructions traitent des diff...

Page 14: ...era d clater ou bien que la pompe risquera d tre endommag e suite aux temp ratures lev es qui se d velopperont 3 Ne pas utiliser un pistolet g chette standard avec cette pompe N utiliser qu un pistole...

Page 15: ...ant l lectricit REMARQUE Les moteurs bitension sont c bl s l usine pour fonctionner sur le courant de 230 volts Au besoin modifier le c blage pour que le moteur fonctionne sur le 115 volts comme il es...

Page 16: ...bord le fil de mise la terre du circuit lectrique puis le fil de mise la terre du moteur sur la borne de mise la terre verte qui se trouve sous le couver cle du moteur se reporter la Figure 5 et ident...

Page 17: ...ancher les fils du condensateur Glisser une cl fourche de 7 16 de po derri re l interrup teur centrifuge ressorts comme il est illustr en la faisant reposer sur les m plats de l arbre du moteur afin d...

Page 18: ...e en carton sur la surface polie du si ge puis pousser cette rondelle en car ton dans la cavit du joint l aide d une douille de 3 4 de po ou d un morceau de tuyau standard de 3 4 de po D S assurer que...

Page 19: ...ur d eau 1 17351 0009 17351 0009 17351 0009 4 Corps de la pompe 1 C2 85 C2 85 C2 85 5 Joint torique 2 U9 430 U9 430 U9 430 6 Joint de l arbre 1 U9 118 U9 118 U9 118 7 Groupe de roues de pompe 1 P325 4...

Page 20: ...aciones nominales de la presi n de descarga de la bomba 4 Peligro de quemadura Nunca permita que la bomba marche en seco Esto podr da ar las piezas internas de la bomba recalentarla lo que provocar a...

Page 21: ...s y Condiciones Generales El comprador debe pagar todos los gastos de mano de obra y transporte nece sarios para reemplazar el producto cubierto por esta garant a Esta garant a no se aplicar a hechos...

Page 22: ...e descarga es de 315 psi La garant a quedar invalidada si se sobrepasan estos l mites de presi n BOMBA DE REFUERZO DE ALTA PRESI N INSTRUCCIONES DE INSTALACI N Estas instrucciones cubren instalaciones...

Page 23: ...igrosa No permita que la bomba marche con la descarga cerrada ya que la manguera puede explotar o la bomba se puede da ar debido a las altas temperaturas 3 No use una pistola a gatillo est ndar con es...

Page 24: ...230 voltios De ser necesario vuelva a conectar el motor para 115 voltios seg n se indica No altere los cables en los motores de una sola tensi n Instale conecte a tierra conecte los cables y mantenga...

Page 25: ...ro el cable a tierra luego el borne verde de puesta a tierra suministrado debajo del techo del motor consulte la Figura 5 identificado como GRD Haga la conexi n a tierra con este borne No conecte el m...

Page 26: ...y retire el capacitor No desconecte los cables del capacitor Deslice la llave abierta de 7 16 por detr s del interruptor centr fugo a resorte seg n se ilustra Col quela sobre los files del eje del mot...

Page 27: ...del asiento y emp jela dentro de la cavidad del sello usando una boquilla de 3 4 o un trozo de tubo est ndar de 3 4 D Verifique que la superficie pulida del asiento no tenga suciedad y no se haya ave...

Page 28: ...17351 0009 4 Unidad de la bomba 1 C2 85 C2 85 C2 85 5 Aro t rico 2 U9 430 U9 430 U9 430 6 Unidad del sello del eje 1 U9 118 U9 118 U9 118 7 Colector vertical de la bomba 1 P325 425 P325 426 P325 439...