Programming Parameters
To enter programming mode, hold the
START
key down for 7 seconds until the
SETUP
indicator
stops flashing. Once programming mode has been entered the
STOP
key can be used to cycle
through the four sub-menu options and the
START
key can be used to view the screens within
each sub-menu. When you wish to enter a screen to update a setting press both the
START
and
STOP
buttons simultaneously and rapidly. When you have successfully entered a screen, the
PROG
signal will flash to indicate that you are now able to edit the setting.
5.1
Preset Menu
Explanation of SETUP-menu 1 – Preset
1
PRESET
1.1 UNIT
This setting determines the measurement unit for Preset and
(Accumulated) Total.
The following can be selected:
L– m3 – kg – LB – GAL – USGAL – bbl – (no unit).
1.2 DECIMALS
The decimal point determines Preset and (Accumulated) Total the
number of digits following the decimal point.
The following can be selected:
0 – 0.1 – 0.02 – 0.003
1.3 K-FACTOR
With the Total K-Factor, the flowmeter pulse signals are
converted to a total unit. The Total K-Factor is based on the
number of pulses generated by the flowmeter per selected
measurement unit (SETUP 1.1). Use SETUP 1.4 to set the decimal
point.
The more accurate the Total K-Factor, the more accurate the
functioning of the system will be.
1.4 K-FACTOR DECIMALS
This decimal point determines for K-Factor (SETUP 1.3) the
number of digits following the decimal point.
The following can be selected:
0 – 0.1 – 0.02 – 0.003 – 0.003 – 0.0004 – 0.00005 – 0.000006