16
5.2
Overrun Menu
Explanation of SETUP-menu 2 – Overrun
Overrun can occur at the end of the batch process, as a result of a slow acting valve or
pump. Consequently, the accuracy is reduced. With this function, the Easybatch analyses
the actual overrun characteristic after every batch and corrects the overrun automatically.
2
OVERRUN
2.1 TIME
Enter the expected time in the range of 0 – 99 seconds, needed by the
system to stop a batch.
With value 0, the overrun function is disabled.
It is advised to provide extra time in order to avoid an incorrect overrun
correction.
2.2 Preclose
In case two-stage batch control is desired, output 2 can be used to be
switched-off before output 1. This switch moment is based on the remaining
quantity before the end of batch.
If pre-close is set to zero, output 2 will switch simultaneously with output 1.
5.3
Meter Menu
5.3.1
Signal Type
The input type can be selected from the following; coil, reed switch, NPN, PNP or NAMUR. The
following table should be referenced when selecting the correct software setting for your
flowmeter.
Instruments delivered integrally mounted to a flowmeter will have this parameter
factory set and do not require user adjustment.
Sensor Type
Used in:
Software
Setting
Maximum
Frequency
Reed Switch
OM Meters
DP Meters
REED
NPN Sensor
OM Meters
– Hall Effect
DP Meters
– Hall Effect
EGM Meters
– Hall Effect
NPN
PNP Sensor
Other manufacturer’s
Flow Meters
PNP
Variable Reluctance Coil
Turbine Flowmeters
Coil
Wiegand Sensor
DP Meters
- Voltage Pulse
Coil