background image

1

3

2

1

2

3

1

2

3

Area "B"

(Both Sides)

Area "A"

(Both Sides)

Retainer Bar

Assembly

Bumper

Guard

Tie Wrap

C-Clips

Product Out

Lines

CO2 Inlet Line

Manifold

(Quick-Disconnect

Reversible Fittings)

Pump

Bracket

Fig #1

Standard Configuraton

Flojet Model No. 5000-530

Installation Operation & Service Instructions

Flojet N5000 Series

CO

2

Operated Beverage Pump

Bracket Assembly

A front installation requires the following hardware, four
#8 Phillips pan head self-drilling sheet metal screws to
mount on “Area A”, which in turn is mounted on the
riser/spacer of the bag-in-box rack (see fig. #1 & #6). On
a side installation, the same hardware is used, but the
area affected is “Area B” (see fig. #8). For wall
installation, four anchor bolts are provided. All pumps/
transfer valves are identified left to right as follows: #3,
#2, #1. On a standard three shelf bag-in-box rack, #3
pump services the top shelf, #2 pump services the
middle shelf and #1 pump services the bottom shelf.
This also applies to the transfer valves. For quick
installations, please note all pumps have the CO

2

inlet

line manifold. Only one CO

2

line is needed from CO

2

source to pump bracket assembly. A 3/8 inch (9.5 mm)
product out (quick-disconnect fitting) stainless steel
barb port is provided with every pump.

Pump bracket assemblies/transfer valve assemblies are
capable of readily accepting installation of Flojet and
Shurflo products. (See fig. #7 for proper removal of
pumps.) Pump bracket assemblies/transfer valve
assemblies adapt to the Red Line bag-in-box rack. (See
fig. #6 for routing of hose and tube hangers.)

All suction line lengths from pump inlet to box connec-
tor must not exceed 10 feet (3 m). Transfer valve is
located between pump and box and now includes 15
feet (4.6 m) of hose for special applications. Pumps must
be above bottom of corresponding box when installed

on bag-in-box rack. When securing bag-in-box rack to
wall, you must allow a nominal one inch (25.4 mm)
clearance between the wall and the rear legs of the rack.

Pump Assemblies With Transfer Valves

Hose length should be no greater that five feet (1.5 mm)
vertical distance between center line of pump and
bottom of box it is pumping from.

Pump Assemblies Without Transfer Valves

Installation on bag-in-box racks must be provided for no
greater than ten feet (3 m) vertical distance between
center line of pump and bottom of box it is pumping
from.

Mounting Hardware For Installation Of Pump &
Transfer Valve Assemblies To Bag-In-Box Rack

1.  Quantity of four #8 Phillips pan head self-drilling

sheet metal screws.

2.  Minimum of two tube hangers per suction hose to

fasten hose to bag-in-box rack.

3.  Quantity of four #8 Phillips pan head self-tapping

screws for use with anchor bolts for wall mounting.

4.  Quantity of four anchor wall mounting anchors.

5.  All Oetiker clamps must be stainless steel and of

step-less design.

6.  Quantity of one plastic tie wrap provided for product

out hose.

OPERATION

Model N5000 Series

Summary of Contents for N5000 Series

Page 1: ...rflo products See fig 7 for proper removal of pumps Pump bracket assemblies transfer valve assemblies adapt to the Red Line bag in box rack See fig 6 for routing of hose and tube hangers All suction line lengths from pump inlet to box connec tor must not exceed 10 feet 3 m Transfer valve is located between pump and box and now includes 15 feet 4 6 m of hose for special applications Pumps must be a...

Page 2: ... gas pressure or manufacturer s maximum recommended pressure The Flojet Model N5000 has an automatic vacuum shutoff valve which stops the pump by shutting off the gas supply to the pump when the bag is empty and high vacuum builds up in the inlet syrup line The control will automatically restart the pump when a new bag is connected and vacuum in the inlet syrup line has returned to normal OPERATIO...

Page 3: ...de of pump with your fingers Do Not use a screw driver for removal of the pump to maintain future retainer bar assembly tension Note The CO2 manifold would change if a Shurflo pump is installed Fig 8 Standard installation of a three pump assembly without a transfer valve on a riser spacer See front mount Front Mount Side Mount Note Tygon Hose Center Line Run N5000 530 ...

Page 4: ...e for installation where altitudes exceed 3 000 feet 914 m Features 1 Supplies up to two fast flow or four standard flow dis pensing valves at remote locations 2 Fully automatic operates only when beverage is being dispensed and maintains constant pressure at the dispensing valve 3 Shuts off automatically when bag is empty and restarts when a full bag is connected 4 High suction capability empties...

Reviews: