P a g e
7 | 15
INLET SETUP
SEE DRAWING ON THE NEXT PAGE FOR SCHEMATIC DRAWING
NOTE: BEFORE COMPLETING INSTALLATION AND GLUING ALL PVC TOGETHER, COMPLETE A DRY RUN TO ENSURE EVERYTHING FITS BEFORE CEMENTING
BEGINS.
TRENCH SIZE REQUIRED: 200MM WIDE X 700MM LONG X 500MM DEEP
FITTINGS REQUIRED FROM FITTING KIT:
•
1 X 100MM BSP SOCKET
•
1 X 100MM MBSP – F SOCKET
•
1 X 100MM – 90MM ADAPTOR
•
1 X 90MM M + F 90 DEGREE ELBOW
•
1 X 90MM M + M 90 DEGREE ELBOW
•
1 X 90MM X 500MM (SUGGESTED) LENGTH STORMWATER PIPE
IMPORTANT!!! DO NOT USE THE INLET FITTING LOCKING NUT AS A TIGHTENING ATTACHMENT POINT DURING INSTALLTION.
THIS CAN POTENTIALLY LOOSEN THE LOCKING NUT AND WILL CAUSE THE FITTING TO LEAK.
ONCE THE FITTINGS HAVE BEEN ATTACHED AND THE BLADDER IS FOLDED BACK OVER (SO THE FITTINGS ARE UNDER THE BLADDER), PLEASE ENSURE THE
DUG TRENCH IS FULLY BACKFILLED AND PACKED WELL.