OVERFLOW SETUP
SEE DRAWING ON THE NEXT PAGES FOR SCHEMATIC DRAWING
NOTE THERE ARE DRAWINGS FOR HORIZONTAL AND VERTICAL DOWNPIPE OVERFLOW SETUPS. PLEASE ENSURE YOU SELECT THE CORRECT TYPE
DEPENDONG ON YOUR SITE REQUIREMENTS.
NOTE: BEFORE COMPLETING INSTALLATION, COMPLETE A DRY RUN TO ENSURE EVERYTHING FITS BEFORE CEMENTING BEGINS.
FITTINGS REQUIRED FROM FITTING KIT:
•
1 X LEAF EATER
TM
ULTRA
•
1 X 90MM M+F ELBOW
•
2 X 90MM TEE PIECE (F+F+F)
•
90MM PIPE TO SUIT
IMPORTANT!!! THE SET HEIGHT OF THE OVERFLOW MUST SUIT THE LISTED HEIGHTS BELOW
FOR THE WIDTH OF THE RAINPAC
TM
BEING INSTALLED.
THE OVERFLOW CAN BE INSTALLED LOWER THAN THE HEIGHT IF REQUIREED.
IT MUST NEVER BE INSTALLED ABOVE THE HEIGHT LISTED.
FAILURE TO DO THIS WILL VOID YOUR MANUFACTURERS WARRANTY.
BLADDERS WIDTH (METRES/MM)
REQUIRED HEIGHT CLEARANCE ( MINIMUM)
1 metre – 1000mm
400mm
1.3 metres – 1300mm
500mm
1.6 metres – 1600mm
650mm
2 metres – 2000mm
715mm
2.3 metres – 2300mm
715mm
2.6 metres – 2600mm
715mm