17
Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3
Connecting the wires
The water level sensor
The white water level sensor (WS) works by capacitance
and is fitted on the outside of the panel behind the weir.
It is wired to the control box and must be put into position
and fastened with the fitted grub screws (GS), it must be
fitted with the red LED facing out. Do not overtighten the
retaining grub screws.
The water level sensor is positioned above the suction
outlet where it detects air when the water level is too low
for proper flow. Make sure the sensor touches the skin of
the tub. A small red sensor is lit when it detects water, it
should be illuminated all the time in normal operation.
The Temperature probe
This is a cable-mounted solid cylinder about 1/4” in
diameter.
The temperature
housing is pre-filled with
silicone grease. Pass the probe through the cable tie
(CT) and insert the metal tip all the way in to the hole
(TS). Tighten the cable tie around the wire (CT) to secure
it in its place.
The Back-up Battery
The back-up battery has a RED XLR lead. The battery
will maintain the lights and control functions during a
power cut. During the float session, it will finish the
session as normal, when finished session, it wait roughly
20 min and will shut down completely, in standby it waits
20 min, then shuts down.
The battery is a 12v lead acid type, charged at 13.4v by
the power supply with a 10A fuse. Take care not to plug
the battery into any other connector!
End of Session Chime
The Interface panel has an end of session chime that
sounds when the float session has come to the end.
WS
GS
TS
CT