17
VT8-600_1000-en-US_AA 10/18
7.
Specifications
7.1 Electrical Specifications
Accuracy is given as ± (% of r least significant digits) at 73.4
F ±9
F (23
C ±5
C) with
relative humidity <80%. Accuracy is specified for a period of one year after calibration.
Function
Range
Resolution
Accuracy
(reading)
‘OL’ Protection
AC Current
100A (VT8-600)
200A (VT8-1000)
0.1A
± (2.5% + 5 digits)
100A (VT8-600)
200A (VT8-1000)
True RMS, Frequency Response 50 ~ 60Hz
DC Current
100A (VT8-600)
200A (VT8-1000)
0.1A
± (2.5% + 5 digits)
100A (VT8-600)
200A (VT8-1000)
Use the DC Zero function to null the display reading
AC Voltage
6.000V
0.001V
± (1.2% + 5 digits)
600V (VT8-600)
1000V (VT8-1000)
60.00V
0.01V
± (1.2% + 3 digits)
600.0V
0.1V
± (1.5% + 2 digits)
1000V (VT8-1000)
0.1V
± (1.5% + 3 digits)
True RMS voltage applicable to 10% ~ 100% of the range
Input Impedance: ≥ 10MΩ; Frequency response 45 ~ 66Hz
DC Voltage
6.000V
0.001V
± (0.8% + 3 digits)
600V (VT8-600)
1000V (VT8-1000)
60.00V
0.01V
600.0V
0.1V
± (1.0% + 2 digits)
1000V (VT8-1000)
0.1V
± (1.0% + 3 digits)
Input Impedance: ≥ 10MΩ
Resistance
600.0Ω
0.1Ω
± (1.2% + 2 digits)
600V DC (VT8-600)
1000V DC (VT8-1000)
600V AC
6.000kΩ
0.001kΩ
± (1.0% + 2 digits)
60.00kΩ
0.01kΩ
600.0kΩ
0.1kΩ
6.000MΩ
0.001MΩ
± (1.2% + 2 digits)
60.00MΩ
0.01MΩ
± (1.5% + 5 digits)
Continuity
600.0Ω
0.1Ω
-----
< 10Ω beeper sounds. 10Ω to 100Ω undetermined. > 100Ω beeper off (OL
displayed). Open circuit voltage approx. 1.2V