5
Operation
5.2.1
Internal moisture sensor
1.
Press the
button to enter the Moisture mode.
The
and
indicators are displayed. The
indicator is also dis-
played, indicating that the meter is displaying relative measurements. The
ambient temperature is displayed on the secondary display.
2.
Place the internal moisture sensor (located on the rear side of the meter) on
the surface of the material to be tested.
The relative moisture reading is displayed on the main display. No units of
measurement are displayed.
3.
Absolute or Zero Mode measurements. This mode allows measurements to
be displayed as a difference between the actual reading and a stored refer-
ence reading. Follow the steps below.
1.
For best results, keep hands and other surfaces and objects away from
the internal moisture sensor area when turning on the unit.
2.
Place the internal moisture sensor on the surface that will be the "refer-
ence" surface. Press and hold the
button for 2 seconds until the
indicator flashes. This will zero the meter at the reference value.
3.
Place the internal moisture sensor on the surface of the material to be
tested. The measurement will be read as the offset value of your stored
reference.
4.
Press and hold the
button for 2 seconds to return to normal inter-
nal moisture measurement mode.
5.2.2
External pin probe
1.
Connect the external pin probe to the EXT connection jack (located at the
bottom of the meter).
2.
Press the
button to enter the Moisture mode. The
indicator is
displayed.
3.
Press the
button once more to activate external pin probe measure-
ments. The
indicator is displayed.
#T559822; r. AE/ 10036/10036; en-US
13
netzerotools.com
netzerotools.com