Setup
5
6. Repeat steps 4 & 5 for as many preset locations as you would like in the tour. When fin-
ished, press
Save
to save the tour.
You can press the
Start
button to test the tour, then
Stop
to stop the test.
To delete a tour:
• Click
next to the tour you want to delete to remove it from the list.
5.3.3
Scan
An auto scan automatically cycles between a set left and right limit.
To add a scan cycle:
1. Under
PTZ > Function
, click
Scan
.
2. Under
Scan No.
, select the scan cycle you would like to configure.
3. Click
Set
.
4. Using the PTZ controls, move the camera to the leftmost point of the scan pattern you
want to set and click
Left Limit
.
5. Move the camera to the rightmost point of the scan pattern you want to set and click
Right Limit
.
6. Under
Speed
, click
-
/
+
or use the slider to set the speed of the scan cycle. Setting a
higher number means the camera will move faster between the left and right limits.
7. Press the
Start
button to test the scan cycle, then
Stop
to stop the test.
5.3.4
Pattern
You can use the pattern function to record a series of camera movements to recall later.
To save a pattern:
1. Under
PTZ > Function
, click
Pattern
.
2. Under
Pattern No.
, select the pattern cycle you would like to configure.
3. Click
Set
.
#LX400038; r. 1.0/18537/18537; en-US