CM-3202-11-I QIG Rev 100
June 2020
This document does not contain any export-controlled information.
d. Drill three anchor holes according to
the template.
e. Hammer the three plastic anchors into
the drilled holes.
f. If the cable from the conduit does not
enter on the side of the camera, drill a
hole for cable entry according to the
template.
g. Place the camera over the
surface and securely fasten
the three tapping screws
clockwise into the plastic
anchors.
h. Check that the camera's
orientation covers the
required field of view.
3.5 Place the Desiccant in the Camera
a. Carefully tear open the vacuum-packed
aluminum desiccant bag along the slit on one
edge.
b. Remove the desiccant.
c. Remove the paper backing of the double-sided
tape on one side of the desiccant.
d. Firmly attach the desiccant to the camera in the
location shown.
Important
·
After placing the desiccant in the camera, attach the
camera cover as soon as possible.
·
To prevent condensation in the camera, tightly seal the
mounts and conduits. Otherwise, the desiccant will become
damp and cannot be used.
4. Configure the Camera
You can configure the camera using the DNA tool, the camera's web page, or a
VMS.
DNA tool
Camera's web page
Discover camera IP address
•
Configure IP address, mask, and gateway
•
•