FLIR Ariel CM-3202-11-I Quick Install Manual Download Page 3

CM-3202-11-I QIG Rev 100

June 2020

This document does not contain any export-controlled information.

Internal interface

Description

6

RS232 terminal block

Not used

3.3 Route Cables and Connect the Camera

System Cable

Connector

Black

RJ-45

Pink

AUDIO OUT

Light green

AUDIO GND

Light blue

MIC IN-

Yellow black

MIC IN+

Purple

ALARM COM

Blue

ALARM OUT

Gray

ALARM IN

White

ALARM GND

Black

12 VDC-

Red

12 VDC+

a. Properly install the power and network cabling in the mounting hardware so that

it is accessible when the camera is mounted.

b. Attach an Ethernet cable from the network switch to the RJ45 connector for a

100 Mbps Ethernet and PoE (Power over Ethernet) IEEE 802.3af Class 3
connection. Ethernet is required for streaming video and for configuring the
camera.

c. Connect the audio, microphone, and alarm connectors, as needed.

d. If using a 12 VDC power supply, connect its wires to the two-pin power terminal

block.

Cables can enter the
camera from the side or
from the bottom.

Side cable entry

Bottom cable entry

3.4 Mount the Camera

a. Be sure to have the required accessories and tools available.

b. Refer to the camera's installation and user guide as necessary.

c. Paste the included drill template onto the wall or ceiling where you are mounting

the camera.

Summary of Contents for Ariel CM-3202-11-I

Page 1: ...t the camera and then unzip the file The DNA tool does not require a license to use and is a free download from FLIR com Products Security Visible Security Cameras FLIR ARIEL CM 3202 2 2 Perform a Ben...

Page 2: ...ty Cameras Accessory Guide 3 Install the Camera 3 1 Fit Mounting Hardware If required install the mounting hardware for the camera according to the instructions for the hardware 3 2 Remove Camera Cove...

Page 3: ...ed b Attach an Ethernet cable from the network switch to the RJ45 connector for a 100 Mbps Ethernet and PoE Power over Ethernet IEEE 802 3af Class 3 connection Ethernet is required for streaming video...

Page 4: ...ew 3 5 Place the Desiccant in the Camera a Carefully tear open the vacuum packed aluminum desiccant bag along the slit on one edge b Remove the desiccant c Remove the paper backing of the double sided...

Page 5: ...on a network with static IP addressing you can manually specify the camera s IP address using the DNA tool or the camera s web page The camera s default IP address is 192 168 0 250 To manually specif...

Page 6: ...Change Video Format Optional By default NTSC is the camera s video format To change the camera s video format to PAL using the DNA tool a In the DNA Discover List right click the camera and select Ch...

Page 7: ...new password for the admin user Use a strong password consisting of at least eight characters and at least one uppercase letter one lowercase letter and one number Passwords can include the following...

Page 8: ...scovery Attach procedures to attach the camera to a VMS 5 Camera Dimensions The Ariel CM 3202 11 I camera s dimensions are Side Dimensions Base Dimensions 6 Register the Product Register your Product...

Reviews: