FLIR A50 Series User Manual Download Page 2

Important note

Before operating the device, you must read, understand, and follow all instructions, warnings, cautions, and legal disclaimers.

Důležitá poznámka

Před použitím zařízení si přečtěte veškeré pokyny, upozornění, varování a vyvázání se ze záruky, ujistěte se, že jim rozumíte, a řiďte
se jimi.

Vigtig meddelelse

Før du betjener enheden, skal du du læse, forstå og følge alle anvisninger, advarsler, sikkerhedsforanstaltninger og
ansvarsfraskrivelser.

Wichtiger Hinweis

Bevor Sie das Gerät in Betrieb nehmen, lesen, verstehen und befolgen Sie unbedingt alle Anweisungen, Warnungen,
Vorsichtshinweise und Haftungsausschlüsse

Σημαντική σημείωση

Πριν από τη λειτουργία της συσκευής, πρέπει να διαβάσετε, να κατανοήσετε και να ακολουθήσετε όλες τις οδηγίες,
προειδοποιήσεις, προφυλάξεις και νομικές αποποιήσεις.

Nota importante

Antes de usar el dispositivo, debe leer, comprender y seguir toda la información sobre instrucciones, advertencias, precauciones y
renuncias de responsabilidad.

Tärkeä huomautus

Ennen laitteen käyttämistä on luettava ja ymmärrettävä kaikki ohjeet, vakavat varoitukset, varoitukset ja lakitiedotteet sekä
noudatettava niitä.

Remarque importante

Avant d'utiliser l'appareil, vous devez lire, comprendre et suivre l'ensemble des instructions, avertissements, mises en garde et
clauses légales de non-responsabilité.

Fontos megjegyzés

Az eszköz használata előtt figyelmesen olvassa el és tartsa be az összes utasítást, figyelmeztetést, óvintézkedést és jogi
nyilatkozatot.

Nota importante

Prima di utilizzare il dispositivo, è importante leggere, capire e seguire tutte le istruzioni, avvertenze, precauzioni ed esclusioni di
responsabilità legali.

重要な注意
デバイスをご使用になる前に、あらゆる指示、警告、注意事項、および免責条項をお読み頂き、その内容を理解して従ってくだ
さい。

중요한 참고 사항
장치를 작동하기 전에 반드시 다음의 사용 설명서와 경고

,

주의사항

,

법적 책임제한을 읽고 이해하며 따라야 합니다

.

Viktig

Før du bruker enheten, må du lese, forstå og følge instruksjoner, advarsler og informasjon om ansvarsfraskrivelse.

Belangrijke opmerking

Zorg ervoor dat u, voordat u het apparaat gaat gebruiken, alle instructies, waarschuwingen en juridische informatie hebt
doorgelezen en begrepen, en dat u deze opvolgt en in acht neemt.

Ważna uwaga

Przed rozpoczęciem korzystania z urządzenia należy koniecznie zapoznać się z wszystkimi instrukcjami, ostrzeżeniami,
przestrogami i uwagami prawnymi. Należy zawsze postępować zgodnie z zaleceniami tam zawartymi.

Nota importante

Antes de utilizar o dispositivo, deverá proceder à leitura e compreensão de todos os avisos, precauções, instruções e isenções de
responsabilidade legal e assegurar-se do seu cumprimento.

Важное примечание

До того, как пользоваться устройством, вам необходимо прочитать и понять все предупреждения, предостережения и
юридические ограничения ответственности и следовать им.

Viktig information

Innan du använder enheten måste du läsa, förstå och följa alla anvisningar, varningar, försiktighetsåtgärder och
ansvarsfriskrivningar.

Önemli not

Cihazı çalıştırmadan önce tüm talimatları, uyarıları, ikazları ve yasal açıklamaları okumalı, anlamalı ve bunlara uymalısınız.

重要注意事项
在操作设备之前,您必须阅读、理解并遵循所有说明、警告、注意事项和法律免责声明。

重要注意事項
操作裝置之前,您務必閱讀、了解並遵循所有說明、警告、注意事項與法律免責聲明。

Summary of Contents for A50 Series

Page 1: ...User s manual FLIR A50 A70 series nbn Austria GmbH...

Page 2: ...tos megjegyz s Az eszk z haszn lata el tt figyelmesen olvassa el s tartsa be az sszes utas t st figyelmeztet st vint zked st s jogi nyilatkozatot Nota importante Prima di utilizzare il dispositivo imp...

Page 3: ...ition monitoring 10 5 1 4 Research development 11 6 Camera parts 12 7 Camera installation 13 8 Mechanical installation 14 9 RTSP Streams 15 10 Camera web interface 16 10 1 Supported browsers 16 10 2 L...

Page 4: ...ftware supported byFLIR A50 A70 series cameras 49 14 Mechanical drawings 50 15 EU Declaration of conformity 52 16 Indicator LEDs and factory reset button 54 16 1 Power error indicator LED and factory...

Page 5: ...face of the product 1 6 Usage statistics FLIR Systems reserves the right to gather anonymous usage statistics to help maintain and improve the quality of our software and services 1 7 Copyright 2021 F...

Page 6: ...owing two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation WARNING Applicab...

Page 7: ...or Air of lower quality than Process air can contain high levels of contaminants Damage to the detector can occur CAUTION Applicability Cameras with an automatic shutter that can be disabled Do not di...

Page 8: ...3 3 Accuracy For very accurate results we recommend that you wait 5 minutes after you have started the camera before measuring a temperature 3 4 Disposal of electronic waste Electrical and electronic...

Page 9: ...prod ucts as well as manuals for our historical and obsolete products 3 7 Important note about this manual FLIR Systems issues generic manuals that cover several cameras within a model line This means...

Page 10: ...l The camera serial number The communication protocol or method between the camera and your device e g SD card reader HDMI Ethernet USB or FireWire Device type PC Mac iPhone iPad Android device etc Ve...

Page 11: ...API to transfer data from the cam era to a web interface or to an application on the internet The Image Streaming cameras deliver images with all related information to a com puter where the user can...

Page 12: ...Sensor camera 3 Ethernet connector X coded 4 Power I O connector A coded 5 Digital output to a programmable logic controller PLC 6 Separate DIN rail power supply for galvanic isolation 18 56 V DC 7 L...

Page 13: ...ing custom made software 2 CAT 6 Ethernet cables 3 Industrial Power over Ethernet PoE switches with fiber optic posts 4 Fiber optic cable 5 FLIR A50 A70 Image Streaming cameras 6 Industrial process to...

Page 14: ...critical assets 1 Computer running custom made software 2 CAT 6 Ethernet cable 3 Industrial power over Ethernet PoE switch 4 FLIR A50 A70 Image Streaming cameras 5 Industrial process to be monitored e...

Page 15: ...heat dissipation on PCB during development 1 Computer running FLIR science software e g FLIR Research Studio 2 CAT 6 Ethernet cable 3 Laboratory setup with a FLIR A50 A70 Advanced Image Streaming cam...

Page 16: ...For details see section 16 Indicator LEDs and factory reset button page 54 2 Ethernet communication indicator LED green 3 Antenna 4 Power I O connector A coded 5 Factory reset button 6 RS232 485 conne...

Page 17: ...the power cable between the camera and a power source for pin config urations refer to the user manual of the FLIR A50 A70 series Connect the net work cable to the camera and then either directly to t...

Page 18: ...ounted on a bracket or heat sink made of a material with a high capacity to transfer heat e g aluminum The use of a cooling bracket or a heat sink is also strongly recommended in order to minimize the...

Page 19: ...ding mpeg4 MPEG4 encoding mjpg Motion JPEG encoding The section after the encoding refers to the source which can be either or ch1 will start a streaming session giving you the identical video as seen...

Page 20: ...ogging in for the first time log in with the username admin and the default ad ministrator password provided by FLIR available on the camera calibration certificate Note The users viewer and user are...

Page 21: ...t tools are labeled with a number for identification ac cording to the order of their creation Added measurement tools show up in the Active measurements section where the they can be managed and wher...

Page 22: ...re scale page 28 5 4 To display how much of the tool is covered by an isotherm select the Iso check box This setting is only applicable if you have selected a color alarm isotherm For more information...

Page 23: ...draw the line to the desired length The tool is labeled with a number and it is also displayed in the Active measurements section 3 To move the tool click and hold the tool label in the image and the...

Page 24: ...ement 10 4 1 6 Delta Use the delta measurement tool to calculate the difference between two measurement results or between a measurement result and a fixed temperature reference temperature To add a d...

Page 25: ...a change in the trigger If the threshold is set above 30 0 C and the hystere sis is set at 2 0 C the trigger goes high when the temperature rises above 30 0 C and stays high until the temperature drop...

Page 26: ...was triggered 5 When completed click Set alarm The alarm is now listed under Active alarms 10 4 2 3 Setting an alarm based on sensor temperature The internal temperature sensor can act as a thermomet...

Page 27: ...bject emits compared with the radiation of a theoretical reference object at the same temperature called a blackbody The opposite of emissivity is reflectivity The emissivity determines how much of th...

Page 28: ...ction click Settings next to the tool for which you want to change the parameters The Settings dialog box appears 2 To activate the use of local parameters select the Local parameters check box The va...

Page 29: ...es within an image A different palette can make it easier to analyze the image The most suitable palette for a certain application depends on many different factors such as the target temperature and...

Page 30: ...the Active measurements section Also a temperature indicator is added to the left side of the temperature scale lo cated to the right of the image 4 To change the threshold temperature click Settings...

Page 31: ...be carried out automatically with different selectable intervals It is also possible to perform a cali bration manually 10 4 7 1 Automatic calibration To set the automatic calibration follow this pro...

Page 32: ...ier to analyze details in the image For example by manually changing the maximum and or minimum temperature levels to levels near a certain object in the image you can study temperature variations in...

Page 33: ...tream To pause or freeze the live image stream follow this procedure 1 On the toolbar and in the View modes section click Freeze 2 To resume the live image stream click Unfreeze 10 4 15 Hiding the ove...

Page 34: ...the camera administrator can approve the client Approved clients can be revoked later on Temporarily enable the Auto approve functionality while setting up the network clients However it is recommend...

Page 35: ...Server address box 2 Set date and time manually Select the correct Time zone in the list and then type date and time information in the Year Month Day Hour Minute and Second boxes 3 Get date and time...

Page 36: ...Connect 10 5 7 3 Streaming bit rate Follow this procedure 1 In the navigation pane click Network settings 2 In the Streaming bit rate list select one of the available bit rates 3 Click Apply 10 5 8 S...

Page 37: ...he Device label box Select the Display in status bar check box to show the camera ID on the active tab of the web browser and in the upper part of saved images 10 6 1 2 Test Digital Input Output Use t...

Page 38: ...w this procedure 1 In the FTP Server box type the IP address of the FTP server 2 In the FTP User and FTP Password boxes type the credentials for the FTP access 3 Click Apply To configure delivery by e...

Page 39: ...hen setting up alarms see section 10 4 2 Working with alarms page 20 10 6 5 2 Analogue out The camera has no analogue outputs but by using the built in Modbus master function ality and an analogue out...

Page 40: ...k Preview 3 To download an image click the image file name and then click Download 4 To delete one or more images click the image file name s and then click Delete 10 7 2 Managing videos To manage vid...

Page 41: ...Pin configurations 11 11 1 Ethernet connector and cable Figure 11 1 Female X coded M12 Ethernet connector Pin Configuration 1 DA 2 DA 3 DB 4 DB 5 DD 6 DD 7 DC 8 DC T810579 r AB 78918 78918 en US 37...

Page 42: ...Pin configurations 11 Figure 11 2 Ethernet cable M12 to RJ45 T810579 r AB 78918 78918 en US 38...

Page 43: ...nd cable Figure 11 3 Male A coded M12 Power Digital I O connector Pin Configuration 1 EXTPWR_RTN 2 EXTPWR_IN 3 FAULT_A 4 FAULT_B 5 DIGOUT1A 6 DIGOUT1B 7 DIGOUT2A 8 DIGOUT2B 9 DIGIN1 10 DIGIN2 11 Not C...

Page 44: ...3 Green 4 Purple 5 Yellow 6 Pink 7 Orange 8 Brown 9 White 10 Grey 11 Light blue 12 Blue 11 3 RS232 RS485 connector Figure 11 5 Male A coded M8 RS232 RS485 connector Pin Configuration 1 RS232_TXD alt R...

Page 45: ...onnection board is an accessory that can be used to test functionality and digital connections to from the camera Figure 12 1 A series connection board For schematics and connection examples see the n...

Page 46: ...A GROUND A B A B 10k 10k DIGIN_1 DIGIN_2 DIGIN_GND DIGIN_1 DIGIN_2 DIGIN_GND FUSE FUSE INDICATOR INDICATOR DIGITAL GROUND TEST DIGIN_1 CAMERA POWER INPUT DIGITAL POWER INPUT DIGITAL OUTPUTS DIGITAL IN...

Page 47: ...A series connection board 12 12 1 Connection examples See next page T810579 r AB 78918 78918 en US 43...

Page 48: ...GIN_2 DIGIN_GND DIGIN_1 DIGIN_2 DIGIN_GND DIGITAL GROUND TEST DIGIN_1 DIGITAL INPUTS TEST DIGIN_2 3 VOLT DROP 3 VOLT DROP JUMPER JUMPER JUMPER DIGITAL POWER 12V REG DIGITAL POWER DIGITAL GROUND TEST D...

Page 49: ...DIGOUT_1A DIGOUT_1B DIGOUT_2A DIGOUT_2B FAULT_A FAULT_B DIGITAL POWER DIGITAL GROUND A B DIGITAL GROUND DIGITAL POWER A B A B 10k 10k DIGITAL OUTPUTS JUMPER JUMPER JUMPER 1 2 3 1 2 3 1 2 3 1 2 3 TEST...

Page 50: ..._A FAULT_B DIGOUT_1A DIGOUT_1B DIGOUT_2A DIGOUT_2B FAULT_A FAULT_B DIGITAL POWER DIGITAL GROUND A B DIGITAL GROUND DIGITAL POWER A B A B 10k 10k DIGITAL OUTPUTS JUMPER JUMPER JUMPER 1 2 3 1 2 3 1 2 3...

Page 51: ...GOUT_2A DIGOUT_2B FAULT_A FAULT_B DIGITAL POWER DIGITAL GROUND A B DIGITAL GROUND DIGITAL POWER A B A B 10k 10k DIGITAL OUTPUTS JUMPER JUMPER JUMPER 1 2 3 1 2 3 1 2 3 1 2 3 Vin Voltage Input Device DI...

Page 52: ...OUND 18 30V 0V CAMERA POWER CAMERA GROUND CAMERA POWER CAMERA GROUND DIGITAL GROUND CAMERA GROUND FUSE FUSE INDICATOR INDICATOR CAMERA POWER INPUT DIGITAL POWER INPUT JUMPER JUMPER 18 30V 0V TEST Exte...

Page 53: ...upported byFLIR A50 A70 series cameras 13 For a list of supported software see the online documentation for the FLIR A50 A70 camera series http support flir com resources 9s26 T810579 r AB 78918 78918...

Page 54: ...Mechanical drawings 14 See next page T810579 r AB 78918 78918 en US 50...

Page 55: ...ICOIL 8mm 0 31in IR Lens 29 deg IR Lens 51 deg Generic dimensions for all FOV 1 2 3 4 5 6 7 8 9 10 1 6 3 2 5 4 A B C D E F G H F C E G D A B Scale 1 1 A Rev Modified R D JOHE Basic dimension Ax0 T1312...

Page 56: ...EU Declaration of conformity 15 See next page T810579 r AB 78918 78918 en US 52...

Page 57: ...Union harmonisation legislation Directives Directive 2011 65 EU RoHS and 2015 830 EU Phtalates Directive 2014 53 EU Radio Equipment Directive RED Standards Emission EN 55032 2015 Electromagnetic Comp...

Page 58: ...a s IP settings are reset to the fac tory defaults DHCP assigned The indicator LED status resumes the status it had before the button was depressed 10 seconds A rapidly flashing red light When the fac...

Page 59: ...it must be dry Do not use a lens cleaning cloth with the liquids that are listed above These liquids can cause material on the lens cleaning cloth to become loose This material can have an unwanted e...

Page 60: ...lishes the relation between emitted radiation the quantity value and the electrical output signal the indication This first step of the calibration procedure consists of obtaining a homo geneous or un...

Page 61: ...rs All FLIR Systems cameras are drift compensated when they are first delivered to the customer and when they are recalibrated by FLIR Systems serv ice departments 18 5 Calibration verification and ad...

Page 62: ...al situation they should all give the same output sig nal However each individual element has its own response so the output is not uniform This deviation from the ideal result is calculated and used...

Page 63: ...s acquired several companies with world leading expertise NEOS 2019 Endeavor Robotics 2019 Aeryon Labs 2019 Seapilot 2018 Acyclica 2018 Prox Dynamics 2016 Point Grey Research 2016 DVTEL 2015 DigitalOp...

Page 64: ...tem elec tronics to final testing and calibration all production steps are carried out and supervised by our own engineers The in depth expertise of these infrared specialists en sures the accuracy an...

Page 65: ...ms operates a worldwide service network to keep your camera running at all times If you discover a problem with your camera local service centers have all the equipment and expertise to solve it withi...

Page 66: ...Notes T810579 r AB 78918 78918 en US 62...

Page 67: ...Notes T810579 r AB 78918 78918 en US 63...

Page 68: ...nge without further notice Models and accessories subject to regional market considerations License procedures may apply Products described herein may be subject to US Export Regulations Please refer...

Reviews: