FAA-26, Technical Manual, Rev. 1.2.0, December 2020
Page
5
of
14
3.
Front View, Features and Specifications
Microcontroller based analogue load cell transmitter FAA-26 has very high accuracy
and long-term stability with its state-of-the-art design.
This high accurate instrument gives the system designers a lot of advantages to
increase the system reliability and to reduce the installation and service times. All
instrument
s’ analogue outputs are matched in the production to perform calibration at
PLC and for changing the instrument without recalibration in service if the adjustment
is done in a PLC.
There are 2 rotary switches and annunciator LEDs in front of the instrument.
The upper rotary switch adjusts
unloaded scale’s analogue output level (zero
adjustment) and the lower rotary switch adjusts the gain of the instrument. The front
view and pin descriptions of FAA-26 are shown below.
Pin
Name
Definition
LOAD CELL CONNECTION
- Ex
- Excitation
+ Ex
+ Excitation
- Si
- Signal
+ Si
+ Signal
ANALOGUE OUTPUT
I
4 - 20mA output
V
0 - 10V output
G
GND
Shield and Protective ground
ANALOGUE OUTPUT RANGE
T
Refer to chapter 4.4
R
Refer to chapter 4.4
G
Ground
NC
Not used
NC
Not used
NC
Not used
POWER SUPPLY
24V
+24VDC
0V
0VDC
FAA-26