Typical Pump Setup

Typical setups for lawn sprinkler pump systems 

include ground water wells (

Fig. 1

) or surface 

water, such as lakes, ponds or streams. (

Fig. 3

)

Location

For best performance, the pump must be located 

as close to the water source as possible and 

protected from the elements.

Ventilation

Ventilation and drainage must be provided to 

prevent damage to the motor from heat and 

moisture.

Freezing

The pump and all piping must be protected from 

freezing. If freezing weather is forecast, drain 

pump or remove completely from the sprinkler 

system.

Water Supply

The water source must be able to supply enough 

water to satisfy the capacity of the pump and 

water needs. See performance chart. 

  WARNING:

 NEVER run pump against a 

closed discharge. Doing so can boil water inside 

pump, causing hazardous pressure in unit, risk 

of explosion and possibly scalding persons 

handling pump. (

Fig. 2

)

Vertical Lift

Vertical lift is the vertical distance from the lowest 

level of the water to the pump intake. The pump 

will move water as long as the pump is within 25 

vertical feet of the water source.

Horizontal Distance

The horizontal distance is the horizontal 

measurement between the pump inlet and the 

water source. This distance may affect the ability 

of the pump to operate. If it is over 60 feet, call 

customer service at 1-866-994-4148.

Pipe And Fittings

Use galvanized steel or NSF PW Schedule 40 

PVC pipe and fittings. This material is designed 

for water pressure and will seal against air 

and water under pressure. Do Not Use: DWV 

fittings, as these are designed for drains without 

pressure and will not seal properly. 

GENERAL PUMP INFORMATION

Water Level

25 ft.

max

Vertical 

Lift

Outlet

Pipe

Inlet

Pipe

Discharge to 

Sprinkler System

60 ft. max.

Inlet pipe to water

Pipe 

Support

Fig 2

Fig 1

Water Level

25 ft.

max

Vertical

Lift

Outlet Pipe

Inlet

Pipe

Discharge to 

Sprinkler System

Inlet pipe to water

Pipe 

Support

60 ft. max.

Motor Cover

Foot 

Valve

Fig 3

  CAUTION:  

The entire system must be 

air and water tight for efficient operation and to 

maintain prime.

Wire Size:

The wire size is determined by the distance from 

the breaker box to the pump motor, and the 

horsepower rating of the motor. See the wire chart 

for proper wire size.

1-1/2 in.  Discharge

2 in.

Suction

Fig 4

Summary of Contents for EL10P1

Page 1: ...ING ELECTRICAL SHOCK ALERT Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupational Safety and Health Act OSHA ELECTRICAL SHOCK ALERT Replace damaged or worn wiring cord immediately ELECTRICAL SHOCK ALERT Do not kink power cable and never allow the cable to come in contact with oil grease hot surfaces or chemicals ELECTRICAL SHOCK ALERT Unit mus...

Page 2: ...iming Plug with Pressure Gauge Used instead of a priming plug alone Helps determine if the pump is primed indicates if the pump is operating properly and what kind of pressure is in the system when operating a 1 1 1 4 in MPT x 1 2 in FPT reducer bushing b 1 1 2 in MPT x 1 4 in FPT reducer bushing c 1 100 PSI pressure gauge 2 Unions Used for easy removal of the pump from the sprinkler system a 2 2 ...

Page 3: ...ve water as long as the pump is within 25 vertical feet of the water source Horizontal Distance The horizontal distance is the horizontal measurement between the pump inlet and the water source This distance may affect the ability of the pump to operate If it is over 60 feet call customer service at 1 866 994 4148 Pipe And Fittings Use galvanized steel or NSF PW Schedule 40 PVC pipe and fittings T...

Page 4: ...top of the pump 2 Glue a 6 in piece of 1 1 2 in pipe into the adaptor 3 Glue a 1 1 2 in tee to the pipe 4 Glue a 1 1 2 in slip x 1 1 4 in adaptor to the top opening of the 1 1 2 in tee 5 Thread in a 1 1 4 in priming plug or optional priming plug with pressure gauge NOTE Hand tighten only as this will be removed for priming 6 Glue another 6 in section of 1 1 2 in pipe into the opening in the 1 1 2 ...

Page 5: ...n in the well 14 Glue a 90º elbow when the inlet pipe is in line with the inlet port of the pump For Surface Water Installations For surface water installations follow steps 11 and 12 above and then 15 Glue a 45º elbow when the inlet pipe is in line with the inlet port of the pump 16 Support inlet pipe with pipe support Fig 12 Fig 11 IL1261 Water Level Discharge to Sprinkler System Well Seal Inlet...

Page 6: ...to the female portion of the 1 1 2 in union 5 Glue 1 1 2 in ball valve to the other end of the 6 in piece of pipe 6 Connect the 1 1 2 in outlet pipe to the sprinkler system by gluing in additional sections of pipe as needed 7 Connect union to ensure proper fit Do not tighten until after priming CAUTION Do not glue union together Water Level Discharge to Sprinkler System Well Seal 100 PSI Pressure ...

Page 7: ...ct with oil grease hot surfaces or chemicals ELECTRICAL SHOCK ALERT The pump must be properly grounded using the proper wire cable with ground ELECTRICAL SHOCK ALERT Always disconnect pump from electricity before performing any work on the motor WARNING ELECTRICAL SHOCK MAY OCCUR All wiring should be performed by a qualified electrician in accordance with the National Electric Code and local elect...

Page 8: ... Connect green ground wire to green grounding screw Re install rear motor cover to pump To change from 230 V to 115 V 6 The motor of pump is dual voltage and can run on either 115 volts or 230 volts In general 230 volts is more economical to run and requires a smaller wire size The pump is pre set in the factory to run at 230 volts 7 For 115 volts service change the following wires on the terminal...

Page 9: ...g and continue adding water to pump cavity until water comes out of the open outlet pipe at the open union 5 Wait 10 minutes to see if water level drops below the pipe tee If level drops check foot valve If level stays constant replace the priming plug 6 Reconnect 1 1 2 in union on outlet pipe Open the ball valve turn handle to line up with pipe and then turn on breaker to start pump IMPORTANT If ...

Page 10: ...kwise to remove from shaft 4 Use a screwdriver to remove the rotary seal B Pry the ceramic seal and rubber gasket from the recess of the mounting bracket Fig 1 CAUTION Be careful not to damage the motor shaft or recess surface 5 Clean the recess and motor shaft thoroughly 6 Install the new rotary seal assembly Fig 2 NOTE To make installation easier apply a drop of liquid soap to the outside diamet...

Page 11: ...eak in inlet line 1 Repair or replace inlet line Use thread tape and pipe sealing compound 2 Vertical lift too high 2 Reduce vertical lift install foot valve and prime 3 Insufficient inlet pressure or suction head 3 Increase inlet pressure by adding more water to tank or increasing back pressure 4 Clogged foot valve or strainer 4 Inspect foot valve and or strainer for debris and remove D Pump vibr...

Page 12: ...4 Standard hardware item NOTE Motor assembly not available as a replacement part PRODUCT SPECIFICATIONS Model HP Suction Lift Ft Discharge Pressure PSI Shut Off Pressure 0 Lift PSI Suction Pipe Discharge Pipe 15 20 25 30 35 40 45 Capacity U S Gallons per Minute SP10P1 EL10P1 1 5 65 61 53 44 32 39 2 in 1 1 2 in 10 64 58 49 39 24 15 62 55 45 34 20 59 51 41 28 25 56 46 36 2 SP15P1 EL15P1 1 1 2 5 66 6...