background image

                                                                                FlinEnergy GPRS Monitoring Device Manual 

 

 Flin Energy

 

2 Preparation  

2.1 Prerequisite  

T

he following devices are required if you’re using GPRS/3G Card or GPRS/3G Box:  

 

For GPRS/3G Card: 

 

1.

 

GPRS/3G card (Diagram 1-1)  

2.

 

Micro SIM Card (12 x 15 mm) as in Diagram 2-1           

3.

 

SMS Device such as

 

cell phone    

4.

 

Monitored device  

     

           

  

 

 

 

GPRS/3G card  

Micro SIM card  

Diagram 2-1  

For GPRS/3G Box: 

 

1.

 

GPRS/3G card (Diagram 2-1)  

2.

 

Micro SIM Card (12 x 15 mm) as in Diagram 2-1  

3.

 

GPRS/3G Box (Diagram2-2)  

4.

 

DB9 to RJ-45 Data Cable (Diagram 2-2) 5.

 

SMS Device such as cell phone  

6.

 

Monitored device.   

Summary of Contents for GPRS

Page 1: ...FlinEnergy GPRS Monitoring Device Manual GPRS Monitoring Device USER MANUAL ...

Page 2: ... 3 2 1 Prerequisite 3 2 2 Installation 4 3 Monitor 5 3 1 Registration 6 3 2 Login 8 3 3 Region Manager 10 3 4 Device Manager 12 3 5 Monitor 13 3 6 User Manager 18 3 7 Email Notification 21 4 System Configuration 22 4 1 SMS Setting 22 5 SMS Notification 29 5 1 Notification of firmware 29 5 2 Prompt Alarm Notification 30 6 Trouble Shooting 30 ...

Page 3: ... and alarm service The users can assign one or multiple numbers to receive the notification Parameter configuration and firmware upgrade can be completed via SMS Diagram 1 1 The usage for GPRS and 3G card is the totally the same If using 3G card it will apply 3G system for data transmission as priority If there is no 3G signal available it will automatically switch to GPRS signal 1 2 Features Uplo...

Page 4: ...ata transmitting 10ms on 3990ms off Online registration succeeded No call and no data transmission 500ms on 500ms off Limited Internet service for example no SIM card no PIN authentication or searching for Internet 1 4 Package Contents Before installation please inspect the unit Be sure that nothing inside the package is damaged during transportation You should have received the following items in...

Page 5: ... 3G Card 1 GPRS 3G card Diagram 1 1 2 Micro SIM Card 12 x 15 mm as in Diagram 2 1 3 SMS Device such as cell phone 4 Monitored device GPRS 3G card Micro SIM card Diagram 2 1 For GPRS 3G Box 1 GPRS 3G card Diagram 2 1 2 Micro SIM Card 12 x 15 mm as in Diagram 2 1 3 GPRS 3G Box Diagram2 2 4 DB9 to RJ 45 Data Cable Diagram 2 2 5 SMS Device such as cell phone 6 Monitored device ...

Page 6: ... Energy GPRS 3G box DB9 to RJ 45 data cable Diagram 2 2 2 2 Installation For GPRS 3G Card 1 Screw the Antenna to GPRS 3G card Diagram 2 3 Diagram 2 3 2 Insert SIM card into the slot Pay attention to the direction of SIM card Diagram 2 4 Diagram 2 4 ...

Page 7: ...with screws Diagram 2 6 3 Connect DB9 terminal of data cable to GPRS 3G Box Diagram 2 7 Diagram 2 7 Diagram 2 8 4 Connect data cable RJ 45 to Inverter or UPS Please refer to the terminal of DB9 in Diagram 2 7 and RJ 45 in Diagram 2 8 5 Use one input power cable to connect to of GPRS Box 3 Monitor If GPRS operates normally it will transmit data via SIM card to data center http power datacenter com ...

Page 8: ...user s experience you are suggested to view the information via suggested browser including Chrome 6 IE10 Firefox 4 0 Safari Besides smart phones and tablets can also access to the data 3 1 Registration 1 Click register now located below the Login button to go to registration page ...

Page 9: ...gy User name Please enter user name and remember it for further use Password It contains 6 ASCII characters including number capital letter and lower case letters Confirm password Re enter the password which should be consistent with the one in Password ...

Page 10: ...ice Manual 8 Flin Energy 2 Click button to complete the registration 3 2 Login After registration you can log in the data center The login page is shown as follow After logging in the main page of data center will be shown as below ...

Page 11: ...nergy GPRS Monitoring Device Manual 9 Flin Energy Location Manager The users can monitor all device in various locations Device Manager The users can bind device s to designated location and assign to users ...

Page 12: ...RS Monitoring Device Manual 10 Flin Energy Monitor It is grouped by location and all devices with assigned location will be listed User Manager Where you create additional users for the account 3 3 Location Manager ...

Page 13: ... edit locations 2 After registration the system will assigned the user an undefined location which can be deleted or edited 3 Click on to start a new location as illustrated below 5 Click on to terminate creation 4 After filling out required fields click on to complete the new location ...

Page 14: ... is on the monitored device Device name Assign a name so that the users can directly identify which card or device it is Device type Select the type of monitoring device Location name Select the bound location of monitored device Click to complete the assignment Click to list the information of bound device 2 Assign device Please refer to section 3 6 under User management for detail instruction ...

Page 15: ...nitor 1 It s grouped by locations and all device in that location will be listed 2 The message will be updated once every 5 minutes Status Current operation status of monitored device 3 Click on to show detail information on a new page Click on to close the window ...

Page 16: ...tion The serial number is shown on the top of the window and operational status indicator is shown as a color dot to the right a Basic information It displays basic information including the voltage current loading temperature etc b Power Information It displays power generation statistics separated into per hour Daily Monthly Annual basis ...

Page 17: ...FlinEnergy GPRS Monitoring Device Manual 15 Flin Energy c Rated information It shows the nominal rated information including input voltage output voltage frequency battery voltage etc ...

Page 18: ... GPRS Monitoring Device Manual 16 Flin Energy d Product Information It shows the product information including model type Main CPU processor version voltage etc Data Historical data of currently monitored device ...

Page 19: ...FlinEnergy GPRS Monitoring Device Manual 17 Flin Energy Event log Historical events of currently monitored device Power generation data log Power generation data of currently monitored device ...

Page 20: ...3 6 User Manager Users can creat additional logins and assign specific GPRS 3G card to a particular login The end user can monitor the device by logging into the data server via assigned GPRS 3G cards 1 Create User Click on to show the login creation window ...

Page 21: ...FlinEnergy GPRS Monitoring Device Manual 19 Flin Energy operation After filling in the required fields click on to complete the ...

Page 22: ...n be assigned to specific end user login Device type Location name The pull down value may vary depending on different devices Device Select Device End user Select one of the end users Click on to complete the assignment Click on to end the creation process Click on to remove existing user s ...

Page 23: ...ls of any kind occurred in the inverter Data server will send alarm notification s to specific e mail addresses Click on the pull down indicator on the upper right hand corner of the screen to begin Select My profile It will prompt you with the following screen and please enter the email address of intended recever Check Email notification box and then click on to confirm your input ...

Page 24: ...g with C is normal command and will be invalid after GPRS 3G card resumes Every command has three possible applied methods CMD stands for concrete commands and C_VALUE stands for current value VALUE represents setting value 1 CMD or CMD means you can search for the current value and trigger command set as default For example C CPWD or C PWD means you can search for current passwords for SMS settin...

Page 25: ...f C CID is C CID which indicates the acceptable range is 1 to 100 ASCII characters 3 A B C A and B are numbers which indicates the setting range is larger than A but smaller than B The interval is a value of arithmetic sequence between B A For example The return value of C UPS is UPS 5 10 86400 which indicates the initial value is 5 and its maximum is 86400 and the tolerance is 5 so 5 10 or 15 is ...

Page 26: ... 10 600 OK ERROR C SNTP SNTP Server SNTP time a nist gov SNTP 1 100 OK ERROR C DBGL Adjusted Level It is not suggested to adjust DBGL 0 DBGL 0 1 10 OK ERROR C FWV Firmware version FWV XXXXXX1 FWV ERROR C SMMG Message Management Multiple telephone numbers can be set to send the alarm and version update notification Different numbers are separated by SMMG SMMG 0 100 OK ERROR C SMAD Messages contains...

Page 27: ...ll auto transfer to local time zone TIMZ GMT 00 00 TIMZ 3 9 OK ERROR C APN Set up access point name APN APN 0 65 OK ERROR C AUPH Auto firmware updated interval The unit is hour 0 means disable AUPH 24 AUPH 0 1 720 OK ERROR C PDCD Parallel data collection PDCD ON PDCD ON OFF OK ERROR C Executive all C type operation commands Return with all information above Return with all information above ERROR ...

Page 28: ... system parameters restore to default settings SPTD OK ERROR SPTD ERROR C CARD Check card type CARD GPRS 3G CARD ERROR C GATT The connection status of Packet Domain service GATT OK ERROR GATT ERROR C QSN The serial number of monitored device QSN QSN ERROR C List all C typed operation command Return with all available C typed commands ERROR ERROR Note 1 This value will be changed 2 The format of re...

Page 29: ...FlinEnergy GPRS Monitoring Device Manual 27 Flin Energy 1 Inquire ID no of GPRS 3G card 2 Set card ID 3 Firmware update 4 Set the interval time of uploading the data 5 Set the password of SMS ...

Page 30: ...FlinEnergy GPRS Monitoring Device Manual 28 Flin Energy 6 Inquiry of daily generated power 7 Multiple commands ...

Page 31: ...y should be separated by If the firmware changes all the numbers in the management group will be notified by SMS notification Please refer to Diagram 5 1 for the example of SMS notification The format of SMS notification for updating firmware ID XXXXXXXXXXXXXX TOPIC FW UPDATE X X X X X X 1 ID GPRS 3G card ID 2 TOPIC Remind the firmware update via SMS notification 3 The version of firmware is X X X...

Page 32: ...ault Refer to Diagram 5 2 for the SMS example Format for alarm notification is ID XXXXXXXXXXXXXX TOPIC ALARM SN CODE DETAIL 1 ID GPRS 3G card ID 2 TOPIC Notify the message is an alarm notification 3 SN Serial Number of monitored device 4 CODE There are four formats WO means there are warnings FO means there are faults WR means the warnings cancel The code number will follows WO FO WR and FR 5 DETA...

Page 33: ...FlinEnergy GPRS Monitoring Device Manual 31 Flin Energy ...

Reviews: