FlinEnergy GPRS Monitoring Device Manual
30
Flin Energy
Diagram 5-1
5.2 Prompt Alarm Notification
1.
Users have to set the numbers for Management Group through C^SMMG command.
If
there are more than one numbers, they should be separated by “,”.
2.
Users should turn on prompt alarm notification through C^SMAR=ON command. The
prompt alarm notification is OFF in default. Refer to Diagram 5-2 for the SMS example.
Format for alarm notification is:
ID: XXXXXXXXXXXXXX
TOPIC: ALARM
SN, CODE,DETAIL
(1.)
ID: GPRS/3G card ID
(2.)
TOPIC: Notify the message is an alarm notification
(3.)
SN: Serial Number of monitored device
(4.)
CODE: There are four formats. WO means there are warnings. FO means there
are faults. WR means the warnings cancel. The code number will follows
“WO,”
“FO,” “WR,” and “FR.”
(5.)
DETAIL: English description of warning or fault.
Diagram 5-2
6 Trouble Shooting
If any abnormal situation occurs, please follow below chart to find out the reasons.