P
7
/Total14
②
User parameters query and setting (both ON and OFF state can set)
How to enter?
◆
Under main interface, press “M” for 3seconds, enter user parameter
query interface, then press
“
+
”
and
“
-
“
button , can query L2 to L9
value
◆
Under user parameter query interface, press “M” button, enter setting
interface, press
“
+
”
and
“
-
“
button, to set the value of current
parameter, press “M” button again, return query interface.
◆
Under user parameters query interface and setting interface, if there
is not operation for 30seconds constantly, system will quit user
parameter query or setting interface automatically, and return
to main interface, press “power” button can return main interface too.
User parameters query and setting (table 3)
Code
Meaning
Setting
range
Factory
setting
L1
Hot water temp drop
for compressor
restart setting
2℃
~
15℃
5℃
L2
Hot water tank
temp setting
30℃
~
F1
55℃
L3
Floor heating water
temp drop for
compressor restart
2℃
~
15℃
5℃
L4
Floor heating
20-
55°C
45℃
L5
Ambient air
temperature below
which electric heater
-
25
℃
~
25
℃
5
℃
Summary of Contents for EEH/18
Page 3: ...P3 Total14 This is for hot water heating working mode optional...
Page 11: ...P11 Total14 Electric connection Wiring diagram...
Page 15: ......
Page 16: ......