Flexit CVR 1000 Assembly Instructions And User Manual Download Page 11

11

 6.3  CVR 4000 Display 

CVR 4000 has a display giving information about the 

machine, Fig. 19. 

Speed level

Shows at which of the five speed levels the machine is 

operating.

Indicator for dust bag/bag filter 

When the dust bag/filter symbol starts flashing 

during operation, the cleaner tells you that it is 

almost time to clean the bag filter and replace the dust bag/

empty the container. When it is time to do so, symbol will be 

lit continuously. The dust bag/filter symbol will be lightened 
after every 20 operation hours of the cleaner at the latest.

Reduced airflow indicator - lit 

The reduced airflow symbol on the display indicates 

that the airflow through the vacuum cleaner is 

reduced. After 30 seconds of operation with reduced airflow, 

the vacuum motor will be shot down in order to prevent 

damage to the motor. If the reduced airflow symbol is lit and 

the motor has been shot down, do like this: Check the bag 

filter and dust bag (see Sections 7.1, 7.2, 7.3 and 7.4) to see 

if anything is blocking the airflow. Also check that nothing is 

blocking suction hose and/or vacuum sockets. Remove the 

material causing the reduced airflow symbol to indicate.

Service indicator

When the service symbol starts flashing, the motor 

will run for one more hour before it stops/will not 

start. The purpose of the service symbol is to inform 

you that it is time to order service of the cleaner. When 

the symbol is continuously lit, the run time counter in the 

cleaner has counted that the allowed amount of run time 

has passed. You must now contact an authorised service 

workshop and let them perform a service of the cleaner and to 

reset the run time counter.

Overheat indicator - flashing 

The overheat symbol indicates that the cleaner has 

become overheated. The cleaner stops automatically. 

Speed

Service

Dustbag/Filter

Wireless

Airflow

Temperature

Dust bag/bag filter

Overheating

Air flow

Signal

Fig. 19

Speed level

Unplug the main power cord to reset the vacuum cleaner and 

wait 5-10 minutes to allow the machine to cool down. While 

you are waiting, check the bag filter, container/dust bag, 

suction hose and vacuum sockets to be sure that nothing is 

blocking the flow of air through the machine.

Signal indicator - flashing

When the symbol is flashing, the hose handle is out of 

range and there is no connection to the cleaner. The cleaner 

will automatically stop after 30 min. if the hose handle or the 

cleaner has not been activated.

Cleaning/replacement is described in 

Section 7

Summary of Contents for CVR 1000

Page 1: ...FLEXIT CVR 1000 CVR 2000 CVR 3000 CVR 4000 Assembly instructions and user guide Central vacuum cleaners 94218E_04 2013 04 ART NR 04010 04020 04030 04040...

Page 2: ......

Page 3: ...4 Symbols used for marking 4 Recycling 4 1 Important safety precautions 4 1 1 Technical data 5 2 Vacuum unit CVR 1000 assembly instructions 6 2 1 Fitting the wall bracket 6 2 2 Locating the vacuum cl...

Page 4: ...the operating instructions carefully Servicing and repairs should only be carried out by an authorised workshop Use only original parts and accessories as recommended by the supplier Never attempt to...

Page 5: ...n power motor 650 Airwatt 720 Airwatt 735 Airwatt 735 Airwatt Max suction power 460 W 490 W 510 W 510 W Max air flow 50 l s 53 l s 54 l s 54 l s Max vacuum 21 kPa 30 kPa 30 kPa 30 kPa Radio remote con...

Page 6: ...tening the four screws Fig 5 5 Fit the blanking plug to the outlet previously occupied by the suction pipe socket Use the four screws to hold it in place The exhaust pipe must be firmly attached to th...

Page 7: ...he hose is removed from the vacuum socket the vacuum cleaner stops Dustpan by the floor Dustpan for mounting in a plinth under a cabinet will start and stop the vacuum cleaner when opened and closed 3...

Page 8: ...tainer so that the filter bulges up slightly Then push the filter down into place Make sure the filter is packed in tightly against the motor housing Fig 13 Reinstall the dust bag and replace the lid...

Page 9: ...y of space above and below the area where the vacuum unit is to be located Make sure there is a minimum of 200 mm free space below the dust container Mark the positions for all four screw holes with a...

Page 10: ...rolled wirelessly from the hose handle of the vacuum cleaner In this case you do not have to mount a low voltage cable between the vacuum socket and the machine On off hose Handle on hose with on off...

Page 11: ...symbol to indicate Service indicator When the service symbol starts flashing the motor will run for one more hour before it stops will not start The purpose of the service symbol is to inform you that...

Page 12: ...hole into the bag holder Fig 23 Fig 21 Fig 20 Fig 23 Fig 22 7 1 Replacing the filter A bag filter must always be installed in the dust container Clean the filter in the following way 1 Release the two...

Page 13: ...g the snap lockings at the connector upwards Secure the low voltage cables at the connector Connect forcing signal to this outlet Forcing signal ventilation unit Connection to units capable of receivi...

Page 14: ...for use The on off function and power regulation is controlled by radio technology Start and stop Start One push at the switch will start the cleaner Stop One push at the switch will stop the cleaner...

Page 15: ...l for overheating will show in the display of the vacuum cleaner Other troubleshootings Are you using the correct hose Only the original hoses fit correctly Does the vacuum cleaner start when you try...

Page 16: ...haking inside the container to loosen dust from the filter and allow it to fall into the container Lift out the bag filter If a dust bag is being used remove it Then empty the dust from the container...

Page 17: ...17 11 Dimensional drawings CVR 1000 CVR 2000 CVR 3000 CVR 4000 M lskisser i mm CVR 2000 CVR 3000 CVR 4000 CVR 1000 66 395 219 115 392 799 Min 200 Min 400 68 44 360 33 115 222 427 38 44 Attach to wall...

Page 18: ...ection to the cleaner Thermal cut out has tripped and the cleaner has stopped See 10 Troubleshooting Signal Overheating Explanation of indication lights at the display for CVR 4000 Bars show the actua...

Page 19: ...19...

Page 20: ...Flexit AS Televeien 15 N 1870 rje www flexit com...

Reviews: