6.7.40. Function 53 - Activating/Deactivating drives
With this function it is possible to activate or deactivate the connected pumps.
N.B. Before activating function 53, ALWAYS first press STOP
If several drives are connected to the system and parallel or serial fills are to be carried out
with fewer drives than those connected, some of the drives must be deactivated.
Press: <5>+<3>+<ENT> and the system will display the number of each connected drive.
Press <Y> for an active drive.
Press <N> for deactivation of the drive.
The system will then go on to the next connected drive and require the same information for
that drive.
When the system has gone through all connected drives, it will leave Function 53.
The next time Function 53 is called, it is possible to connect the deactivated drives again.
6.7.41. Function 58 - Set Passwords
This functions sets the passwords for the 3 different levels.
Level 1 – Unlimited access.
Level 2 – Basic functions
Level 3 – Restricted to <calib> and 59 (Change access level) only.
This function will enable the supervisor to key in passwords for the 3 levels.
By entering function 58, the command line will first prompt for password for level 1, key in the
4 digits and press ENT, the command line will then prompt for level 2 and so on for level 3.
When the three passwords are entered and the system are still in access level 1.
Passwords can be only be erased by entering function 58 in access level 1 and manually
deleting the entered passwords.
Passwords must consist of 4 digits and be different for the 3 levels