![Flexco H-Type Installation, Operation And Maintenance Manual Download Page 14](http://html1.mh-extra.com/html/flexco/h-type/h-type_installation-operation-and-maintenance-manual_2304571014.webp)
12
H-Type
®
Precleaner with XF2-Tips
6.4 Blade Replacement Instructions
Section 6 – Maintenance
Tools Needed:
• Tape measure
• (1) M10 (17mm) wrench or crescent wrench
• (2) M24 (36mm) wrenches or crescent wrenches
• Wire brush (for cleaning pole)
• Small putty knife (for cleaning pole)
1. Remove the tension. Loosen the adjusting nuts on both sides and
then turn them out until they are flush with the ends of the pivot
arms (Fig. 1). This releases the tension of the blade on the belt.
Physically lock out and tag the conveyor at the power source
before you begin cleaner installation.
2. Remove the worn tips. Remove the nuts on each tip and remove the
tips from the suspension arm (Fig. 2). Clean all fugitive material from
the pole.
NOTE:
If tips are hard to remove use a screwdriver or hammer to
loosen it and then remove.
H-Type® Precleaner with XF2-Tips
XF2 Replacement Tip
Adjusting Nuts
Pivot Arm
Fig. 1
Fig. 2
Removal Nuts
Removal Nuts
XF2 Tip