Page 16
Master Programming Mode
CAUTION: Before entering Master Programming, please contact your local professional water dealer.
11. Day Override (Display Code DO)
Press the Extra Cycle button. Use this display to set the Day Override. This setting specifies the maximum
number of days between regeneration cycles. If the system is set to a timer-type control, the day override setting
determines how often the system will regenerate. A metered system will regenerate regardless of usage if the
days since last regeneration cycle equal the day override setting. Setting the day override value to “OFF” disables
this function. This option setting is identified by “DO” in the upper left hand corner of the screen. Use the Up and
Down buttons to adjust the value as needed.
Range: Off-99 days
12. Regeneration Time
Press the Extra Cycle button. Use this display to set the Regeneration Time. This setting specifies the time of day
the control will initiate a delayed, manually queued, or day override triggered regeneration. This option setting is
identified by “RT” in the upper left hand corner of the screen. Use the Up and Down buttons to adjust the value as
needed.
13. Regeneration Cycle Step Times
Press the Extra Cycle button. Use this display to set the Regeneration Cycle Step Times. The different
regeneration cycles are listed in sequence based on the valve type selected for the system, and are identified
by an abbreviation in the upper left-hand corner of the screen. The abbreviations used are listed below. If the
system has been configured with the “OTHER” valve type, the regeneration cycles will be identified as R1, R2,
R3, R4, R5, and R6. Each cycle step time can be set from 0 to 199 minutes, or “OFF.” Setting a cycle step to
“OFF” will disable all of the following steps. Setting a cycle step time to 0 will cause the control to skip that step
during regeneration, but keeps the following steps available. Use the Up and Down buttons to adjust the value as
needed. Press the Extra Cycle button to accept the current setting and move to the next parameter.
Cycle Step
Abbreviation
BD
Brine Draw
BF
Brine Fill
BW
Backwash
RR
Rapid Rinse
SV
Service
Range: 0-199 minutes
Summary of Contents for 7000SXT
Page 23: ...Page 23 Notes...
Page 24: ...Page 24 Powerhead Assembly 12 16 6 13 1 2 5 4 7 9 10 11 3 8 15 14 17 11 18 11 BR61501 7000SXT...
Page 39: ...Page 39 Injector Flow Data TR18755_REVB...
Page 40: ...Page 40 Meter Flow Data TR18753 Softener TR18688 Filter 41140 02_REVA...
Page 41: ...Page 41 Dimensions 41023_REVC...
Page 42: ...Page 42 Notes...