Page 10
Master Programming Mode Chart
CAUTION: Before entering Master Programming, please contact your local professional water dealer.
Master Programming Options
Abbreviation
Parameter
Option
Abbreviation
Options
DF
Display Format
GAL
Gallons
Ltr
Liters
Cu
Cubic Meters
VT
Valve Type
St1b
Standard Downflow/Upflow Single Backwash (Not Used)
St2b
Standard Downflow/Upflow Double Backwash
(7000 Default)
Fltr
Filter (7000 Default)
UFbF
Upflow Brine First (Not Used)
8500
TwinFlo100SXT (Not Used)
Othr
Other (Not Used)
dFFF
Downflow Fill First (Fixed Fill)
IF
Air Injected Oxidizer, AIO Valve Only.
CT
Control Type
Fd
Meter (Flow) Delayed
FI
Meter (Flow) Immediate
tc
Time Clock
dAY
Day of Week
NT
Number of Tanks
1
Single Tank System
2
Two Tank System (Not Used)
TS
Tank in Service
U1
Tank 1 in Service
U2
Tank 2 in Service (Not Shown)
C
Unit Capacity
Unit Capacity (Grains)
H
Feedwater
Hardness
Hardness of Inlet Water
RS
Reserve Selection
SF
Percentage Safety Factor
rc
Fixed Reserve Capacity
SF
Safety Factor
Percentage of the system capacity to be used as a re-
serve
RC
Fixed Reserve
Capacity
Fixed volume to be used as a reserve
DO
Day Override
The system’s day override setting
RT
Regen Time
The time of day the system will regenerate
BW, BD, RR,
BF
Regen Cycle Step
Times
The time duration for each regeneration step. Adjustable
from OFF and 0-199 minutes.
NOTE: If “Othr” is chosen under “Valve Type”, then
R1, R2, R3, etc, will be displayed instead
Summary of Contents for 7000SXT
Page 23: ...Page 23 Notes...
Page 24: ...Page 24 Powerhead Assembly 12 16 6 13 1 2 5 4 7 9 10 11 3 8 15 14 17 11 18 11 BR61501 7000SXT...
Page 39: ...Page 39 Injector Flow Data TR18755_REVB...
Page 40: ...Page 40 Meter Flow Data TR18753 Softener TR18688 Filter 41140 02_REVA...
Page 41: ...Page 41 Dimensions 41023_REVC...
Page 42: ...Page 42 Notes...