› Q U I C K   S TA R T

To the right are the program settings for your softener.  

If not all of the values are filled in, you can calcu-
late the missing values on pages 4 and 5 of this 
guide.

 There we will cover identifying the 3 essential 

values of 

H - HARDNESS

C - UNIT CAPACITY

and 

BF - BRINE FILL

. The remaining values that are  

already filled in are general standards for all softener 
sizes and hardness levels.

MASTER PROGRAMMING MODE:

 To enter in/check 

the adjacent values of your system, follow these steps: 
With either the up or down arrow button, change the 
clock to 12:01 PM, set the time by clicking the left-
most CYCLE / REGEN button, and then hold both the 
up and down arrow buttons for 5 seconds to enter 
master programming mode. Change values with the 
arrow buttons and set each value and advance to the 
next setting by clicking the CYCLE / REGEN button.

A more in-depth guide to programming the Fleck 
5800 SXT is provided beginning on 

page 12

.

O U T L E T

I N L E T

D R A I N

S E T T I N G

I N P U T   VA L U E

DF - Display Format

GAL - Gallons

VT - Valve Type

5800

RF - Regeneration Flow

dF1b

CT - Control Type

Fd - Flow Delayed

C - UNIT CAPACITY

        ,000 Grains

H - HARDNESS

       Grains per Gallon

RS - Reserve Selection

SF

SF - Safety Factor

15%

DO - Day Override

14 Days

RT - Regen Time

2:00 AM

BW - Backwash

10 Minutes

BD - Brine Draw

60 Minutes

RR - Rapid Rinse

12 Minutes

BF - BRINE FILL

       Minutes

FM - Flow Meter Type

t0.7 or P0.7

RE - Time Relay

OFF

VR - Flow Relay

OFF

B R I N E

P O W E R

› G E N E R A L   R E F E R E N C E

Please take a moment to review this page in 
order to familiarize yourself with these ports on 
the valve and the programming values below. It is 
crucial not to mistake the inlet port with the outlet 
port. Mistaking and reversing the inlet and outlet 
ports will lead to failure of your softener system.

As you work through this guide, please make 
sure to follow all instructions exactly and to make 
special note of the bolded instructions and warn-
ing symbols. 

PDF viewers may click underlined 

text to jump to that page or the page number 
in the bottom corner of every page to jump to 
the table of contents.

 All our installation guides 

may be found on our site under “Information.”

FM - Flow Meter Type

                    t0.7

                   P0.7

Summary of Contents for 5800 SXT

Page 1: ...FLECK 5800 SXT METERED WATER SOFTENER INSTALL ATION GUIDE V1 0...

Page 2: ...age 12 OU T L E T IN L E T DR AIN SE T TING INPU T VA LUE DF Display Format GAL Gallons VT Valve Type 5800 RF Regeneration Flow dF1b CT Control Type Fd Flow Delayed C UNIT CAPACITY 000 Grains H HARDNE...

Page 3: ...ntrol Valve from QualityWaterForLess com We have put together these instructions as reference and to be used as general installation guidelines It is always recommended that a licensed plumber perform...

Page 4: ...hardness level in PPM or mg L please divide this number by 17 1 to get Grains gpg Ex If your hardness is measured at 300 PPM take 300 17 1 18 gpg before iron 3 H COMPENSATED HARDNESS Your Iron result...

Page 5: ...20K 10 Min 7 5 lbs Grid Grid NO GRID NO GRID 25 gpg 24K 14 Min 11 25 lbs Grid 3 Legs Grid Grid Grid 32K 1 0 cu ft 9x48 0 12 gpg 20K 8 Min 6 lbs Grid NO GRID NO GRID NO GRID TOO LARGE TOO LARGE 12 25 g...

Page 6: ...IG U R E 6 A FIG U R E 6 B PRE INSTALL ATION Before assembly of your new system be sure that the following conditions have been met for the place ment of your system Level firm surface such as concret...

Page 7: ...E 7 A FIG U R E 7 B 3 INSTALLING THE FLECK 5800 SX T VALVE 1 Remove the filling funnel and tape and while using the included silicone lubricant packet lu bricate the inner and outer o rings on the bot...

Page 8: ...lines and use a wet rag on the lines being soldered to prevent heat damage during soldering 6 Once all connections have been made place the system into bypass by either using your existing 3 valve byp...

Page 9: ...lso take this moment to prepare and insert the brine support grid determined from pages 4 and 5 Then pull the 474 Brine Float Assembly out of the brine well as shown in Figure 9 C 4 Next fix the 474 B...

Page 10: ...e to recut the end of the tube each time you remove it to ensure a proper seal when the tube is inserted 8 Finally use inner diameter I D tubing to connect the drain barb fitting on the brine tank to...

Page 11: ...ure 11 C Be sure that the fitting is fully inserted into the drain port by clicking it into place 4 Reinsert the drain fitting pin to lock the DLFC barbed drain fitting into the Fleck 5800 SXT con tro...

Page 12: ...u may hold the button to allow the time to scroll faster Once the time display is set to 12 01 PM press the REGEN button once as shown in Figure 12 B 3 To enter MASTER PROGRAMMING MODE press the UP an...

Page 13: ...your water listed on page 2 calculated on page 4 and press the REGEN button as shown in Figure 13 C 10 The display should now show RS SF as shown in Figure 13 D This indicates that the Reserve Select...

Page 14: ...igure 14 A This indicates the system will regenerate at 2 00 AM following the day the water consumption has passed the calculated capacity If you prefer an alternate regeneration time please enter it...

Page 15: ...wn in Figure 15 B This indicates Flow Relay Off Do not change this value and advance 21 The system will now exit Master Program ming mode and the display should now show the time of day followed by th...

Page 16: ...of water needed to cover the brine grid into the brine tank Start the regeneration sequence by HOLDING the REGEN button for 5 seconds Once the screen stops flashing BW let BW Backwash run for about 1...

Reviews: