background image

Printed in U.S.A.

Page 4

3200ET Remote Meter

Installation and Start-Up Procedures (Cont’d.)

9. Manually initiate a regeneration  cycle  of all valves in the  system  through the remote  timer. Allow water  to run to

drain on each valve for 3 to 4 minutes. Manually step each valve through a complete regeneration cycle checking
valve operation in each step.       

A. Initiating Regeneration (Depending on the timer regeneration type you have one or two (2) Options):

1.

Press and Release the Extra Cycle Button. With Immediate Regeneration Timers the control will go into
regeneration immediately. With Delayed Regeneration Timers the Service Arrow will begin to flash immedi-
ately and a regeneration will occur at the preset regeneration time (i.e. 2:00 a.m.)

 2.  Press and Hold for 5 seconds the Extra Cycle Button. The control will go into regeneration immediately.

Delayed Regeneration Timers Only)

B. Control Operation While Sending A Regeneration Signal:

1.  When sending a regeneration signal the control will display the remaining signal time.

2.

A red LED will also turn on to indicate that a regeneration signal is being sent.

3.

Pushing the  Extra  Cycle  Button  during  a regeneration  signal  will immediately advance the  timer  back to
Service.

4.  Pushing the Up or Down Set Button during a regeneration signal will adjust the signal time remaining. Pro-

grammed signal time will not be changed.

5.  Once  the  Regeneration  Signal  has  been  completed  the  timer  will  return  to  service  and  resume  normal

operation.

10. A  9V  Alkaline  battery  is  recommended  to  be  installed  at  all  times  for  proper  timer  operation.  The  control  will

indicate when the battery needs to be replaced by turning on the Low Battery LED.

For Example:
(Timer is sending a 6.0 minute 
regen. signal)
(Regeneration arrow on)

Regeneration
Signal

For Example:
(Timer has sent 3.5 min. 
of a 6.0 min. signal))
(2.5 minutes of signal time remain)
(Regeneration arrow on)

Regeneration
Signal

Summary of Contents for 3200ET

Page 1: ...IMPORTANT Fill in pertinent information on page 2 for future reference 3200ET Remote Meter Service Manual...

Page 2: ..._______________________________ ______________________________________________________________________________ 1 Follow the installation procedures contained within the remote meter service manual 2 T...

Page 3: ...to regeneration including any reserve capacity Without any water usage the Meter Arrow should be either off or on but not changing Open a soft water tap The Meter Arrow should begin flashing at a rate...

Page 4: ...generation Timers Only B Control Operation While Sending A Regeneration Signal 1 When sending a regeneration signal the control will display the remaining signal time 2 A red LED will also turn on to...

Page 5: ...ted water is used the Volume Remaining Display will count down from a maximum value to the calculated reserve capacity Once this occurs the Reserve Arrow will begin to flash as an indication that rese...

Page 6: ...nsor Delayed Regeneration Systems In Normal Operation the Time Of Day Display will be viewed at all times The control will operate normally until a valid sensor input signal is received Once this occu...

Page 7: ...t Control Operation During Regeneration During Regeneration a special regeneration display will take the place of either the Time Of Day or Volume Remaining Display This display will contain the numbe...

Page 8: ...ys Depressing the button once will display flow rate Depressing the button again will display the total accumulation of water flow through the meter since it was last reset Depressing the button once...

Page 9: ...Printed in U S A Page 9 3200ET Remote Meter Timer Wiring Diagram Standard Remote Meter Wring 2900 3900 Multivalve System 7 Remote Meter Wiring...

Page 10: ...Printed in U S A Page 10 3200ET Remote Meter 3200ET Timer Assemblies See opposite page for parts list...

Page 11: ...ery Clip 11 1 9V Alkaline Battery Not Included 12 1 14723 Pin Timer Hinge 13 2 10300 Screw Hex Washer 8 x 3 8 Not Shown 1 17749 00 Relay SPDT 24V 1 17749 01 Relay SPDT 120V 1 17749 02 Relay SPDT 240V...

Page 12: ...P N 19488 Rev 4 05 01...

Reviews: