3200ET Remote Meter
Installation and Start-Up Procedures (Cont’d.)
9. Manually initiate a regeneration cycle of all valves in the system through the remote timer. Allow water to run to
drain on each valve for 3 to 4 minutes. Manually step each valve through a complete regeneration cycle checking
valve operation in each step.
A. Initiating Regeneration (Depending on the timer regeneration type you have one or two (2) Options):
1.
Press and Release the Extra Cycle Button. With Immediate Regeneration Timers the control will go into
regeneration immediately. With Delayed Regeneration Timers the Service Arrow will begin to flash immedi-
ately and a regeneration will occur at the preset regeneration time (i.e. 2:00 a.m.)
2. Press and Hold for 5 seconds the Extra Cycle Button. The control will go into regeneration immediately.
Delayed Regeneration Timers Only)
B. Control Operation While Sending A Regeneration Signal:
1. When sending a regeneration signal the control will display the remaining signal time.
2.
A red LED will also turn on to indicate that a regeneration signal is being sent.
3.
Pushing the Extra Cycle Button during a regeneration signal will immediately advance the timer back to
Service.
4. Pushing the Up or Down Set Button during a regeneration signal will adjust the signal time remaining. Pro-
grammed signal time will not be changed.
5. Once the Regeneration Signal has been completed the timer will return to service and resume normal
operation.
10. A 9V Alkaline battery is recommended to be installed at all times for proper timer operation. The control will
indicate when the battery needs to be replaced by turning on the Low Battery LED.
For Example:
(Timer is sending a 6.0 minute
regen. signal)
(Regeneration arrow on)
Regeneration
Signal
For Example:
(Timer has sent 3.5 min.
of a 6.0 min. signal))
(2.5 minutes of signal time remain)
(Regeneration arrow on)
Regeneration
Signal