background image

ABOUT YOUR NEW FLAVEL WARWICK

The Flavel Warwick coal effect gas fire incorporates a unique and highly

developed fuel bed which gives the realism of a loose coal layout combined with

realistic flames and glow. The use of durable hard ceramic material in the

construction of the fuelbed components ensures long and trouble free operation.

When first using the new fire a slight smell may be noticed. This is due to starch

used in the manufacture of the soft ceramic coals, it is non-toxic and will soon

disappear.

Please take the time to fully read these instructions as you will then be able to

obtain the most effective and safe operation of your fire.

IMPORTANT SAFETY INFORMATION

WARNING

This appliance has a naked flame and as with all heating appliances a

fireguard should be used for the protection of children, the elderly and

infirm. Fireguards should conform to B.S. 8423 : 2002 should be fitted.

(Fireguards for use with gas heating appliances).

It is important that this appliance is serviced at least once a year by a CORGI

registered gas installer and that during the service the fire is removed from the fire

opening and the chimney or flue visually checked for fallen debris or blockages

which must be removed. The chimney should also be checked to ensure clear-

ance of flue products. We recommend that during the annual service, replace-

ment of the Oxypilot is carried out.

These are conditions of the manufacturers

guarantee.

After installation or during servicing a spillage test must always be carried

out.

Rubbish of any type must NEVER be thrown onto the fuel bed, this could affect

safe operation and damage the fire.

Any debris or deposits should be removed from the fuel bed from time to time.

This may be carried out by referring to the cleaning section as described later in

this book.

Only the correct number and type of coals must be used and only complete and

genuine replacement sets must be used.

Always keep furniture and combustible materials well clear of the fire and never

dry clothing or items either on or near to the fire. Never use aerosols or flamma-

ble cleaning products near to the fire when it is in use.

3

Summary of Contents for Warwick FIRC**MN

Page 1: ...COAL EFFECT GAS FIRE User Instructions Hand these instructions to the user Model No s FIRC MN FIRC MN are only for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I E denotes trim fret...

Page 2: ...e made additional ventilation is normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domestic Gas Installation which is issued by the Nat...

Page 3: ...this appliance is serviced at least once a year by a CORGI registered gas installer and that during the service the fire is removed from the fire opening and the chimney or flue visually checked for...

Page 4: ...at up if the pilot goes out when the control knob is released repeat the lighting sequence In the unlikely event of a failure of the igniter the fire can be lit as follows Depress the control knob and...

Page 5: ...as been allowed to fully cool CLEANING THE BRASS AND PAINTED METAL PARTS Dependent upon the trim option chosen for use with this fire there is a variety of methods that can be chosen to clean the trim...

Page 6: ...not lodged on the burner See fig 1 below Fig 1 b Place the left hand front coal rail moulding onto the front ceramic rail support as shown below in Fig 2 Fig 2 6 NOTE The position of the fuel bed com...

Page 7: ...c Place the right hand front coal rail moulding onto the front ceramic rail support as shown below in Fig 3 Fig 3 d Fit four large coals behind the ceramic front rails as shown below in Fig 4 Fig 4 7...

Page 8: ...small coals and fit onto the ribs of the fuel bed base See fig 5 below Fig 5 f Select the remaining four small coals and arrange along the rear of the fuelbed directly behind the third row of coals Se...

Page 9: ...ls If any coals are missing please contact your retailer Do not proceed with the installation Fig 7 h Ensure the flame paths are un interrupted as shown below in Fig 8 If necessary make minor adjustme...

Page 10: ...posed of at a landfill licensed to accept such waste Protective clothing is not required when handling these articles but we recommend you follow the normal hygiene rules of not smoking eating or drin...

Page 11: ......

Page 12: ...t the exact accuracy of descriptions and illustrations cannot be guarantee Part no B 103820 Issue 2 BFM Europe Ltd Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ www bfm europe com Telephone Gene...

Reviews: