FRET INFORMATION
To enable Customers to choose their own style of fret these fires are now available
without frets. In order to maintain the efficient and safe operation of the fire it is
important that any fret which is used must comply with the following dimensions.
(figure 27). It is important to clean a fret in accordance with the instructions
provided by your retailer as these vary depending on the surface finish of the fret.
Fig. 27
PARTS SHORTLIST
Replacement of parts must be carried out by a competent person such as a GAS
SAFE registered gas installer. The part numbers of the replaceable parts are as
follows, these are available from BFM Europe who may be contacted at the
address shown on the rear cover.
Fuelbed base
B-58690
Fuelbed front rails (L/H & R/H)
B-18730
Replacement coal set
B-61340
RC gas control valve
B-106790
RC control board
B-129140
RC battery cable
B-106810
RC battery holder
B-106820
Piezo igniter
B-1320
Ignition wire manual control models
B-39030
Ignition wires slide control models
B-50380
Ignition wire remote models
B-63650
Manual gas valve
B-102880
Slide gas valve
B-40980
Remote valve
B-106790
Maximum
Height
210mm
Two Air Slots each of
Minimum Area 19cm2
Minimum Total Open
Area of Fret 110cm2
38