![Flavel RENOIR RC Installation, Maintenance & User Instructions Download Page 54](http://html1.mh-extra.com/html/flavel/renoir-rc/renoir-rc_installation-maintenance-and-user-instructions_2303362054.webp)
Due to our policy of continual improvement and development the exact
accuracy of descriptions and illustrations cannot be guaranteed.
Part No. B-178940
Issue 3
BFM Europe Ltd
Trentham Lakes
Stoke-on-Trent
Staffordshire
ST4 4TJ
www.bfm-europe.com
Telephone - General Enquiries :
(01782) 339000
Telephone - Service :
(0844) 7700169 or (01782) 339008
TROUBLE SHOOTING ADVICE FOR REMOTE CONTROL MODELS PRIOR
TO REQUESTING A SERVICE CALL
Please locate the Indicator light on the control valve, located behind the fender at the
right hand side of the fire (see figure 5 & 6 on page 40), if it shows
any
of the following
flashing sequences then the problem requires the batteries in the control valve and / or
handset changing,
be advised that service calls as a result of batteries requiring
being changed in the product or handset are chargeable.
a)
If the red indicator light flashes
ONCE
every ten seconds the batteries in the
control valve require changing, see section 5.4
b)
If the red indicator light flashes
TWICE
every ten seconds the batteries in the
handset require changing, see section 5.4
c)
If the red indicator light flashes
THREE
times every ten seconds the batteries in
the control valve and the handset require changing, see section 5.4
If these red indicator light flashes are ignored then eventually this will show as a flash
every second and your fire will cease to operate until the batteries are changed.
If a permanent red indicator light is shown after attempting to ignite the fire this signifies
no spark or no gas at the pilot and therefore a service call will be required to diagnose
the fault.
PLEASE ENSURE THIS ADVICE IS FOLLOWED TO AVOID BEING CHARGED FOR A
SERVICE CALL AS A RESULT OF BATTERIES REQUIRING TO BE CHANGED.