2.4
GAS TIGHTNESS
a)
Remove the pressure test point screw from the inlet elbow and fit a
manometer.
b)
Turn on the main gas supply and light the fire as described in section
2.7 and carry out a gas tightness test.
c)
Check that the gas pressure is 20.0 mbar (± 1.0 mbar), 8.0 in w.g. +/-
0.4 in w.g.
d)
Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas tightness with the
appliance turned on using a suitable leak detection fluid or detector.
2.5
COMPLETING THE ASSEMBLY
a)
Fit the radiants by carefully inserting the upper end first into the radiant
canopy, and then lowering and seating the base of the radiants into the
radiant support channel.
b)
Pull off the control knob.
c)
Fit the outer case by hooking rear edge of the case over the retaining
lugs at each end of the rear panel.
d)
Ensure that the control bezel situated in the right hand side of the case
clears the control valve spindle.
e)
Re-fit the outer case fixing screws situated at the front as shown in Fig.
3 & 4 (page 9 &10 respectively)
f)
Refit the control Knob.
2.6
FITTING THE BATTERY
a)
The battery holder is located at the bottom R/H/S of the fire, unscrew
the cap, fit the AA battery supplied in the loose items pack and re-fit the
cap. See Fig. 7 below.
Fig. 7
13
Spark Generator
AA Battery
Battery Cap