1.4
SHELF POSITION
The fire may be fitted below a combustible shelf providing there is a minimum dis-
tance of 200mm above the top of the fire and the shelf does not project more than
150mm. If the shelf overhangs more than 150mm the distance between the fire
and the shelf must be increased by 15mm for every 25mm of additional overhang
over 150mm.
1.5
HEARTHS
This appliance must only be installed on to a level concrete or non-combustible
hearth. The feet must not be removed when installing directly onto a hearth.The
hearth material must be a minimum thickness of 13 mm with the outer perimeter of
the hearth panel at least 50 mm above the floor level, to discourage the placing of
carpet or other floor coverings over it. The hearth must be fitted symmetrically
about the fire opening and have a minimum width of 760 mm and a minimum
projection of 350 mm forwards from the fire opening.
SECTION 2
INSTALLATION OF FIRE
2.1
UNPACKING THE FIRE
Carefully lift the fire out of the carton. Remove the loose item packaging carefully
from the the pack. Check the contents as listed :-
DO NOT UNDER ANY CIRCUMSTANCES USE THIS APPLIANCE IF THE
GLASS PANEL IS BROKEN OR NOT SECURELY FIXED TO THE FIREBOX.
Packing Check List
Pack 1 of 1
1off
Combustion chamber / burner assembly
1off
2 piece fuel-bed set (packed in seperate carton)
1off
Flue pipe and flue terminal unit
1off
Installation & Maintenance Instruction Book
1off
User Instruction Book
1off
Loose items pack
1off
Cooler plate
2off
Brass finials - to be screwed into casting upon commisioning
2off
Decorative side trims & 4 off side trim fixing screws
Pack 2 of 2
1off
Cast iron canopy assembly