Guider IIS series User Guide | www.flashforge.com
5-3
(5-3) When it shows that the distance is too big, please unscrew all three nuts
under platform clockwise for the same rounds until hearing a steady beep and
the [Verify] button appears.
5-4
(5-4) If the distance is appropriate, tap [OK] to second point leveling. If still not,
please follow the prompts to adjust the first point screw again till you see [OK]
button.
5-5
(5-5) Repeat steps according to the prompts on the touch screen to complete
second and third points leveling and then finally Tap [Finish] to exit.
Leveling operating has completed
!