FLARE-100 (FLARE-FF, FLARE-ST, FLARE-RC, FLARE-LC, FLARE-DC, FLARE-RD)
CONNECTING 3X5 PIPE
The Flare Power Vent system uses DuraVent 3x5 CVS vent system. The DuraVent CVS vents includes a lock system and a silicone
gasket on every side of the vent. Make sure you follow the DuraVent CVS installation manual:
http://duravent.com/docs/product/l916.pdf
Please follow the vent marking for directing of vent flow. The direction is clearly marked on the 3x5 vents, the Fireplace vent
adapter, and the Power Vent adapters. See the pictures below for clarification on the Power Vent system vent connection:
Run Length
Restrictor Setting
Burner Type
Unit Type
12--28
3
H
Flare 100
28--40
3
H
Flare 100
40--52
2
H
Flare 100
52--64
1
H
Flare 100
64--76
1
H
Flare 100
76--88
1
H
Flare 100
88--100
1
H
Flare 100