25
En
able to change a parameter, press the
CONFIRM
button
„6“
OK
.which causes blinking of
the parameter field to be changed. By pressing
“+”
(4)
or
“-” (5
) one can alter its value.
If there are more parameter fields on the screen (e.g. setting the clock) then one will go among
them by pressing the
CHOOSE
button
„7“
. By clicking the
CONFIRM
button
„6“
OK
one confirms the changes - the parameter field stops blinking. The changed parameter not confir-
med for 10 secs is not accepted by the control unit and it recalls a previous value of the parameter.
ON/OFF
ON/OFF
CONFIRM
CHOOSE
Fig. 2 Control panel view
1. Control unit status diode:
- alarm (red),
- standby (orange),
- operation (green),
- manual
MAN
(blinking green)
2. Graphic display
3. Button F1:
switch-on/off power supply
4. Increase button
5. Decrease button
6. Confirmation button
7. Parameter selection button
8. Button F2
(for producer)
3.1 Time zones
! In the default settings the time zones are turned off. In order to activate them you need to set the
<14>
Time zones parameter to
ON
.
The control unit is equipped with the clock, which enables the automatic change of the control
unit operation at different times of day. 24 hrs are divided into 5 time zones
($1, $2, $3, e4, e5)
and the single time when no zone is active that is
ZONE 0
or
BAZA (BASE)
. Each zone has a start
time
FROM
and an end time
TO
. The same start and end time means the zone isn’t active, which
doesn’t change the settings of the control unit. The time zones can overlap each other in that case
binding are the settings for the active zone of higher number.
In the control unit there’s a zones program. In order to activate it you need to set the
<14>
Time
zones parameter to
ON
.
ZONE $1
FROM 6.00 TO 8.00
ZONE $2
FROM 14.00 TO 17.30
ZONE $3
FROM 20.00 TO 22.30
ZONE $4
FROM 23.00 TO 5.00
ZONE $5
FROM 8.00 TO 13.30